Traulsen RET232EUT-FHS, RET132EUT-FHS, RET232EUT-HHS IV. Operation cont’d, Care & Maintenance

Page 5

IV. OPERATION (contd)

V. CARE & MAINTENANCE

IV. g - ADJUSTING THE TEMPERATURE SCALE:

The Traulsen Even-Thaw model is preset at the factory to operate within strict temperature parameters. Should these settings require adjustment, please contact our Service Department at (800) 825-8220.

IV. h - OPERATOR CONTROLS, BLOWER SWITCH:

As delivered from the factory, all RET models are preset to operate as described in section IV B. However, if needed the unit can also be set to operate as a high ca- pacity refrigerator.

To accomplish this a Blower Switch is located behind the cabinet louvers towards the center. It is labeled ON/OFF. As delivered, this is in the ON position, allowingthe unit to operate in the even-thaw mode. When in the OFF posi- tion, this disables two internal mullion blowers, allowing the unit to operate as a high capacity refrigerator.

Return the Blower Switch to the ON position prior to at- tempting another even-thaw batch. Failure to do so will result in increased thaw times.

IV. i - CALL SERVICE LIGHT:

This red light is located above the front panel thermom- eter. If illuminated, it may indicate a failure or problem with one of the temperature sensing probes inside the Even- Thaw unit. If one of the temperature sensing probes fail, the unit will default to a preset refrigeration cycle in an at- tempt to maintain safe product temperatures. The refrig- eration system and fans will continue to function.

If the light is illuminated, the unit WILL NOT function in the thaw mode until the faulty component is repaired. If illumi- nated, contact your authorized service agent.

V. a - CLEANING THE CONDENSER:

The most important thing you can do to insure a long, reliable service life for your Traulsen is to regularly clean the condenser coil.

The condensing unit requires regularly scheduled clean- ing to keep the finned condenser clean of lint and dust accummulation. Keeping the condenser clean allows the cabinet to operate more efficiently and use less en- ergy.

To clean the condenser, first disconnect electrical power to the cabinet and lift up the front louver assembly. To lift this, remove the two screws located on both sides at the bottom of the louver assembly (see figure 3). Once the screws are removed, the panel can be pivoted up- wards allowing full access to the front facing condenser (see figure 4). Vacuum or brush any dirt, lint or dust from the finned condenser coil, the compressor and other cooling system parts. If significant dirt is clog- ging the condenser fins, use compressed air to blow this clear.

Lower louver assembly and replace the screws to hold it in place.

Fig. 3

Fig. 4

V. b - HINGE REPLACEMENT:

Both the door and hinge can be easily removed from the cabinet. To remove the door, remove the plug at the bottom of the top hinge. Inside the hinge there is a small screw which secures the door in place. Remove this with a flat head screwdriver and the door can then be lifted off the hinge. To remove the door portion of the hinge from the door, lift off the hinge cover and then remove the three Phillips head screwswhich secure the hinge in place on the door. To remove the cabinet por- tion of the hinge, remove the three Phillips head screws which hold it in place. On solid door units, the top hinge(s) contains a microswitch for controlling the interior lighting.

To reassemble the hinge reverse the previous procedure.

-4-

Image 5
Contents OWNER’SMANUAL Serial TAG Table of ContentsII. Receipt Inspection III. InstallationIV. Operation III. Installation cont’dIV. Operation cont’d Care & MaintenanceVI. Other Care & Maintenance cont’dVI. a INTRODUCTION/OVERVIEW VII. General USE, Operation & Service SummaryONE Section Models VIII. Expected Thaw PERFORMANCE/OPERATIONAL TroubleshootingIX. Trouble Shooting Guide VIII. Operational Troubleshooting cont’dSpare Parts List XI. Wiring Diagram ALL ONE Section Models only Page Page Standard Domestic Warranty XIV. Warranty InformationXV. Index Quality Refrigeration

RET132EUT-HHS, RET232EUT-HHS, RET132EUT-FHS, RET232EUT-FHS, RET232NUT-FHS, RET232NUT-HHS specifications

Traulsen is a renowned manufacturer of commercial refrigeration equipment, and their RET232NUT-FHS, RET232NUT-HHS, RET232EUT-FHS, RET132EUT-FHS, RET232EUT-HHS, and RET132EUT-HHS models stand out for their reliability, innovative technology, and overall performance.

The RET232NUT-FHS and RET232NUT-HHS are designed primarily for heavy-duty kitchen environments, featuring a robust stainless steel exterior for durability and easy cleaning. These models offer excellent temperature control, ensuring food safety and quality. The electronic control system allows for precise temperature adjustments and monitoring, helping to maintain ideal conditions for stored items.

One of the primary characteristics of the RET series is its high-efficiency refrigeration system. These models utilize environmentally friendly refrigerants that comply with industry regulations, balancing performance with sustainability. Rapid pull-down capabilities are essential in commercial settings, and Traulsen’s units are equipped with powerful compressors that ensure quick temperature recovery, even in the busiest kitchens.

The RET232EUT-FHS and RET132EUT-FHS models also bring similar features to the table, but with additional advancements in user experience. They have integrated LED lighting, which not only enhances visibility inside the unit but also minimizes energy consumption. This is an important factor for establishments looking to reduce their operational costs while maintaining high standards of service.

In terms of versatility, the RET232EUT-HHS and RET132EUT-HHS models cater to diverse storage needs, featuring adjustable shelving that can accommodate various container sizes and formats. This flexibility is crucial for operators who require customization for different products. The self-closing doors are another valuable feature, ensuring optimal temperature retention while facilitating efficient access.

Safety is paramount in commercial kitchens, and Traulsen’s units incorporate numerous safety features, including integrated door locks and alarms to warn of temperature fluctuations or other operational issues. Furthermore, these refrigerators are designed for easy maintenance, with removable gaskets and access to components, allowing service technicians to perform routine checks efficiently.

Overall, the Traulsen RET series embodies a commitment to quality, performance, and innovation. With features that prioritize energy efficiency, user-friendliness, and safety, these refrigeration units are ideal for any kitchen looking to enhance productivity and ensure food safety. Whether it’s the RET232NUT-FHS or the RET132EUT-HHS, operators can confidently rely on Traulsen’s expertise in commercial refrigeration technology.