ELECTRICAL INSTRUCTIONS

A.Before your new unit is connected to a power supply, check the incoming voltage with a voltmeter. If anything less than 100% of the rated voltage for operation is noted, correct immediately.

B.All units are equipped with a 7 ft. (2.1m) service cord, and must be powered at proper operating voltage at all times. Refer to cabinet data plate for this voltage.

True requires that a sole circuit be dedicated for the unit. Failure to do so voids warranty.

WARNING

Compressor warranties are void if compressor burns out due to low voltage.

WARNING

Power supply cord ground should not be removed!

NOTE

To reference wiring diagram - Remove lower rear grill. Wiring diagram is positioned on the inside cabinet wall.

STARTUP

A.The compressor is ready to operate. Plug in the unit.

B.The temperature control is set at the No. 4 position from the factory. Allow unit to function several hours, completely cooling cabinet before changing the control setting.

C.Excessive tampering with the control could lead to service difficulties. Should it ever become necessary to replace temperature control, be sure it is ordered from your True dealer or recommended service agent.

NOTE

If the unit is disconnected or shut off, wait five minutes before starting again.

RECOMMENDATION

Before loading product we recommend you run your True unit empty for two to three days. This allows you to be sure electrical wiring and installation are correct and no shipping damage has occurred. Remember, our factory warranty does not cover product loss!

REPLACEMENT PARTS

TRUE maintains a record of the cabinet serial number for your unit. If at any time during the life of your display case, a part is needed, you may obtain this part by furnishing the model number and serial number to the company from whom you purchased the cabinet. Call Toll-Free: (800)-424-TRUE (Direct to Parts Department). (800)-325- 6152 (U.S.A. & Canada only) or call: (636)-240-2400.

Serial Number

REMOTE UNITS (This section applies to remotes only!)

Remote cabinets must be ordered as remote. We do not recommend converting from a standard self contained to remote system.

All remote cabinets must be hard wired.

No castors available.

All remote cabinets come standard using 404A refrigerant.

All remote units come standard with expansion valve, liquid line solenoid, heated condensate pan, and defrost timer when applicable.

Contact True Technical Service for BTU requirements.

No wiring necessary between cabinet and condensing unit.

All remote condensing units purchased from True are 208/230 volts single phase.

If you have any questions regarding this section, please call True at 1-(800)-325-6152.

9

www.truemfg.com

9

Image 11
Contents True Dipping Cabinets Horizontal Dipping Cabinets Page Safety Precautions Risk of Child Entrapment HOW to Safely Dispose of Used Freezer EquipmentUSE of Extension Cords HOW to Connect ElectricityLocating Installation / Operation Instructions OwnershipRequired Tools UncratingNSF Approved Sealants Sealing Cabinet to FloorVentilation Cabinet DrainUnit Leveling With Castors Installation of Optional Legs and CastorsRemoving Kickplate Optional Dipwell for TDC Models Installing DipwellDrill Hole Centered on Startup Electrical InstructionsStorage Shelving Installation / Operation for TDC Models onlyStorage / Loading Product for TDC Models only ShelvingManual Defrost Temperature ControlTemperature Control Adjustment For High Altitude Step Cleaning the Condenser CoilMagnetic ICE Breaker only on TDC Models Maintenance CleaningStainless Steel Equipment Care and Cleaning Light Bulb Replacement Light Bulb Replacement for TDC ModelsWarranty Information U.S.A. & Canada only