Whirlpool W10032070 GAS Conversions, LP Gas Conversion, To Convert Gas Pressure Regulator

Page 12

GAS CONVERSIONS

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

NOTE: Gas conversions (from natural gas to LP gas or from LP gas to natural gas) must be done by a qualified person.

LP Gas Conversion

WARNING

Tip Over Hazard

A child or adult can tip the range and be killed.

Connect anti-tip bracket to rear range foot.

Reconnect the anti-tip bracket, if the range is moved.

Failure to follow these instructions can result in death or serious burns to children and adults.

To Convert Gas Pressure Regulator

1.Ensure that the manual shutoff valve is in the closed position.

A

C

B

A. Shutoff valve in “open” position

A. Shutoff valve in “open” position

B. Gas supply line

C. To range

2.Unplug or disconnect power.

3.Open broiler door and remove broiler pan. The gas pressure regulator is located in the back right hand corner of the broiler compartment.

A

A. Gas pressure regulator

IMPORTANT: Do not remove the gas pressure regulator.

NOTE: Do not remove the spring beneath the cap.

4.Remove the cap from the gas pressure regulator using a flat- blade screwdriver.

5.Turn the cap over so that LP is visible.

A

A. Cap

6.Reinstall the cap.

To Convert Surface Burners

1.Remove burner grate, burner caps, and burners.

A

B

A. Burner cap

B. Burner

12

Image 12
Contents Installation Instructions 30 76.2 CM Freestanding GAS Range W10032070Range Safety Table of ContentsWhat to do if YOU Smell GAS Installation Requirements Tools and PartsLocation Requirements Product Dimensions Installation Clearances Width For tall Backguard Models CountertopElectrical Requirements Gas Supply RequirementsType of Gas Gas Supply LineGas Supply Pressure Testing Burner Input RequirementsGas Pressure Regulator Installation Instructions Install Anti-Tip BracketUnpack Range Verify Anti-Tip Bracket Location Level RangeMake Gas Connection Typical rigid pipe connectionIf the low flame needs adjusting Check OperationElectronic Ignition System Check Operation of Cooktop BurnersComplete Installation If the flame needs adjustingCheck Operation of Oven/Broil Burner If range does not operate, check the followingGAS Conversions LP Gas ConversionTo Convert Gas Pressure Regulator To Convert Surface BurnersComplete Conversion To Convert Oven BurnerNatural Gas Conversion Install natural gas orifice spuds Whirlpool Corporation All rights reserved 07/2006