Page 13

2.Locate LP gas orifice spuds for top burners in the bag containing literature included with the range. Three LP gas spuds are stamped “88” and one “96.”

3.Remove natural gas orifice spuds using a 7mm combination wrench.

4.Install LP gas orifice spuds.

NOTE: Depending on model, the range cooktop may be equipped with 4 standard burners or 3 standard burners and 1 power burner. Spud size/location remain the same.

A

B

A.Spud

B.Holder

Std burner 88

Std burner 88

Power burner 96

Std burner 88

To Convert Oven Burner

1.Open oven door and remove oven racks, oven tray, flame spreader and set aside.

2.Lift oven burner. The orifice spud is behind the oven burner air shutter.

3.Locate LP gas orifice spud stamped “56” in literature package supplied with range.

4.Use a ³⁄₈" combination wrench and remove the natural gas orifice spud.

A

A. Air shutter

5.Install the number “56” LP gas spud.

A

A. LP oven orifice spud stamped with “56”

IMPORTANT: Do not over tighten.

6.Place natural gas oven burner spud in plastic parts bag along with natural gas cooktop burner spuds for future use and keep with bag containing literature.

7.Reinstall oven burner.

8.Reinstall oven racks, oven tray and flame spreader.

5.Place the natural gas orifice spuds in the parts bag for future use and keep with bag containing literature.

6.Reinstall burners, burner caps and burner grates.

Complete Conversion

1.Refer to the “Make Gas Connection” section for properly connecting the range to the gas supply.

2.Turn the manual shutoff valve in the gas supply line on.

3.Refer to the “Check Operation” section for proper burner ignition, operation, and burner flame adjustments.

IMPORTANT: You may have to adjust the “LO” setting for each cooktop burner.

Checking for proper cooktop and oven burner flames is very important. The small inner cone should have a very distinct blue flame ¹⁄₄" to ¹⁄₂" (6.4 mm to 13 mm) long. The outer cone is not as distinct as the inner cone. LP gas flames have a slightly yellow tip.

4.Close the broiler door and turn the knob to “OFF”.

5.Refer to the “Complete Installation” section to complete this procedure.

13

Image 13
Contents W10032070 Installation Instructions 30 76.2 CM Freestanding GAS RangeTable of Contents Range SafetyWhat to do if YOU Smell GAS Tools and Parts Installation RequirementsLocation Requirements Width For tall Backguard Models Countertop Product Dimensions Installation ClearancesGas Supply Requirements Electrical RequirementsType of Gas Gas Supply LineBurner Input Requirements Gas Supply Pressure TestingGas Pressure Regulator Install Anti-Tip Bracket Installation InstructionsUnpack Range Level Range Verify Anti-Tip Bracket LocationMake Gas Connection Typical rigid pipe connectionCheck Operation If the low flame needs adjustingElectronic Ignition System Check Operation of Cooktop BurnersIf the flame needs adjusting Complete InstallationCheck Operation of Oven/Broil Burner If range does not operate, check the followingLP Gas Conversion GAS ConversionsTo Convert Gas Pressure Regulator To Convert Surface BurnersTo Convert Oven Burner Complete ConversionNatural Gas Conversion Install natural gas orifice spuds Whirlpool Corporation All rights reserved 07/2006