Cornelius WCC1401-A service manual Semi-Annually

Page 12

Continuous Flow Icemaker Service Manual

Semi-Annually

Semi-Annually in addition to all previously established service procedures perform the following:

1.Check for water leaks in tube connections, water fittings and lower icemaker water seal.

2.Check drain tubes for clogs and aged tubes. Replace if tubes are stained or brittle.

3.Check for signs of condensation. Clean where necessary and replace insulation properly.

4.Check safety circuits for proper operation.

5.Check refrigeration system.

6.Check unit for abnormal noise. Tighten machine and cabinet screws if necessary.

7.Check white upper bearing on auger assembly. If bearings are less than 1/16” thick, replace.

OK

REPLACE

1/16

1/16

OK

 

REPLACE

FIGURE 6. UPPER NUT AND BEARING ASSEMBLY

Publication Number: 630460324SER

- 8 -

© 2006-2008, IMI Cornelius Inc.

Image 12
Contents Continuous Flow Icemaker Continuous Flow Icemaker Table of Contents Page Safety Safety InstructionsSafety Tips Qualified Service Personnel Shipping and StorageSpecification Chart General DescriptionSeries WCC1401-A/WCF1411-A Dimension Drawing Schematic WCC1401-A/WCF1411-A ElectricalRefrigeration Schematic DryerWCC2001QTR Refrigeration Diagram Cleaning and Sanitizing Icemaker Cleaning and Sanitizing ProceduresMaintenance Semi-Annually Refrigeration System Adjustments Refrigeration SystemPumpdown Cycle Expansion ValveTo Replace Water Level Safety Switch Water Level ControlHOW Water Level Control Works Purpose of Water Level ControlBIN Control GearmotorGearmotor Overload Tripped To Replace Gearmotor Assembly Motor CheckStart Relay Installation and Shaft Seal Replacement Upper NUT and Bearing AssemblyAuger and Extruding Head Removal Safety Controls Electrical CheckoutOverload Check Compressor CheckCustomer Comments Troubleshooting Troubleshooting Chart Icemaker not OperatingIMI Cornelius Inc