Continuous Flow Icemaker Service Manual
CUSTOMER
COMMENTS
“It runs but the ice is too soft.”
“The icemaker is not producing enough ice.”
“The ice is too wet.”
GUIDE T O GOOD ICE
CHECK ICEMAKER LOCATION CONDITIONS FIRST
Proper air flow for condens- ing system.
Location too close to high units such as coffee urns, deep fryers, grills, etc.
Supply water conditions
Water too warm (above 90oF).
Water artificially softened above 262 ppm sodium chlo- ride.
Normal water supply too high in total dissolved solids (above 500 PPM).
CHECK ICE MAKER
Use gauges for checking suction and head pressures. See manual for correct reading and conditions. Check frost line and sight glass.
Check water level for proper adjustment and restrictions. See Manual.
Check evaporator assembly for worn parts, bearings, scored evaporator and auger, bad expansion valve. etc.
“It makes too much noise.”
(With this comment the ice is usually extremely hard and larger than normal.)
Over Compression
Check to see if noise | Check for loose parts |
objection is normal fan and | and screws rattling. |
air flow noise. | Check evaporator |
| |
Supply water conditions. | assembly for worn |
| parts, bearings, scored |
Water too cold (below | evaporator and auger, |
50oF). (Possibly running | bad expansion valve, |
from | etc. |
Obstructions partially |
|
blocking ice exit from top of |
|
evaporator. |
|
Check fan and fan shroud. |
|
Publication Number: 630460324SER | - 16 - | © |