MOTOR CHECK

The resistance readings on the winding will be between 5 to 25 ohms. A meter capable of these low readings must be used. The start relay cover must be removed.

If no continuity on start or run winding test, replace gearmotor. If continuity on grounded motor test, replace gearmotor.

START RELAY

1.Check between “2” and “4” on relay (with relay unplugged). If there is continuity replace the relay, as the relay contacts should be open.

2.Check between “3” and “4” on relay, if no continuity replace the relay.

FIGURE 14. GEARMOTOR ASSEMBLY

TO REPLACE GEARMOTOR ASSEMBLY

1.Disconnect the icemaker from the electrical power source.

2.Disconnect the transmission cable from the electrical box.

3.Remove the 4 hex head bolts securing the evaporator to the top of the transmission.

4.Remove the 4 bolt’s holding the transmission and bracket to frame base, while supporting the weight of the evaporator. Remove the transmission from the unit.

5.When replacing the transmission, it may be necessary to rotate the auger back and forth to align the motor shaft and auger.

AUGER NUT

AUGER

 

BEARING NYLON

BEARING DELRIN

“D” DRIVE

GROOVE

EXTRUDING

HEAD

ANTI–ROTATION

RIB – 3 PLACES

FIGURE 15. AUGER AND EXTRUDING HEAD REMOVAL

© 2004-2005, IMI Cornelius Inc.

- 15 -

Publication Number: 630460174SER

Image 19
Contents Continuous Flow Icemaker Continuous Flow Icemaker General Description Publication Number 630460174SER 2004-2005, IMI Cornelius Inc Qualified Service Personnel Shipping and Storage SafetySafety Instructions Safety TipsGeneral Description Specification ChartSeries 500 & 700 Dimension Drawing Shipping WT LBS. Approx Series WCC2001-A and WCF2201-A Dimension Drawings Gearmotor BIN ControlMonthly Cleaning and SanitizingIcemaker Cleaning and Sanitizing Procedures MaintenanceSEMI-ANNUALLY Upper NUT and Bearing AssemblyPurpose To Replace Water Level Safety SwitchWater Level Control HOW Water Level Control WorksElectrical Schematic and Wiring Diagram WCC2001-A and WCF2201-AWCF711-W, WCF1101-A, & WCF1101-W Schematic and Wiring Diagram WCC2001-R and WCF2201-R Expansion Valve Refrigeration System AdjustmentsAdjustment and Troubleshooting Refrigeration SystemExpansion Valve Condenser Modulating ValveGearmotor Overload Tripped Condenser Modulating Valve RemovalMotor Check To Replace Gearmotor AssemblyStart Relay Auger and Extruding Head Removal Installation and Shaft Seal ReplacementUpper NUT and Bearing Assembly Installation and Shaft Seal Replacement 700Electrical Checkout Compressor Check Overload CheckCapacitor Check Safety Controls Customer Comments Troubleshooting Chart Icemaker not Operating TroubleshootingIMI Cornelius Inc