2.F POOR ICE QUALITY

YES

IS

 

 

ICE CLOUDY?

 

 

NO

 

 

IS

NO

 

ICE SOFT?

 

 

YES

 

1.CHECK AIR PUMP.

2.CHECK ADJUSTMENT OF TIMER CAM #4. (WATER PUMP)

3.CHECK TIMER SWITCH #4.

4.CHECK WATER DUMP VALVE.

5.CHECK WATER FILTER.

6.INCREASE WATER DUMP BY ADJUSTING TIMER CAM #4.

7.INSTALL ADDITIONAL WATER TREATMENT DE- VICES FOR SPECIFIC PROBLEM WATER.

DONE

27

90914

Image 30
Contents Dispenser Table of Contents Table of Contents cont’d General Information DescriptionInstallation Instructions InstallationUnpacking Instructions Electrical Wiring Installation Instructions Installation Dimensions Mounting Template Model SID 851/250-B Mounting Template Model SID 851/250-BC Beverage System START-UPBeverage System Schematic B Models Beverage System Schematic -BC Models Harvest Cycle Time Cam Switch Action Operating InstructionsWiring Schematic SID 850/250 Wiring Diagram SID 850/250 208--230/115V, 1 PH, 60HZ Refrigeration Schematic Maintenance Cleaning InstructionsDispenser Section 90914 Troubleshooting Guide Start Does Unit OPERATE? No Operation of ANY Component 90914 NORMAL? ICE Maker Problem YES RUN RUN/STOP Stop Hopper YES Present AT No ICE on Evaporator Harvest YES Timer Dump Adjust ICE Thickness Probe only After ALL OTH LOW ICE Production 90914 Dispenser Problem YES Does 90914 MAINTENANCE/ADJUSTMENT Procedures BIN ThermostatICE Thickness Adjustment Harvest Time Adjustment Harvest Timer Parts List Description Part NumbersParts List CONT’D Air Cooled Water Cooled Refrigeration Components 250 250 BCWarranty Remcor Incorporated Regency Drive Glendale Heights, IL 708