MAINTENANCE/ADJUSTMENT PROCEDURES

THERMOSTAT ALTITUDE ADJUSTMENTS

IMPORTANT: Adjust the bin thermostat setting only if storage hopper over fill is a problem.

BIN THERMOSTAT

1.Open the hinged service door.

2.The adjustment screw is located below the “Flush”switch on the left side of the electrical box.

3.For altitudes up to 6,000 feet, turn the adjustment screw COUNTERCLOCKWISE as follows:

ELEVATION (FEET)

COUNTERCLOCKWISE TURN

2,000

1/13

4,000

1/6

6,000

1/4

4. For altitudes above 6,000 feet, consult the factory.

CLEARING EVAPORATOR FREEZE-UP

WARNING: To prevent possible injury, do not place fingers or hand into ice maker nozzle or hopper with power applied to the unit.

1.Open the hinged service door.

2.Place the “Stop/Run”switch in the “Stop”position.

3.Close the water supply valve to the ice maker.

4.Remove the ice drop and hopper covers.

5.Depress the “Flush”switch push button and drain the evaporator.

6.Pour hot water into the evaporator ice exit opening. It will be necessary to use either a funnel or a container with a spout. Fill the evaporator completely.

7.Drain the evaporator. Repeat steps 5 and 6 as required to ensure that all the ice in the evaporator is melted.

8.Open the water supply valve. Depress the fill switch and refill evaporator.

9.Replace the ice drop and hopper covers.

10. Consult TROUBLESHOOTING GUIDE to determine cause of freeze-up before putting unit back in service.

90914

30

Image 33
Contents Dispenser Table of Contents Table of Contents cont’d Description General InformationInstallation Instructions InstallationUnpacking Instructions Electrical Wiring Installation Instructions Installation Dimensions Mounting Template Model SID 851/250-B Mounting Template Model SID 851/250-BC START-UP Beverage SystemBeverage System Schematic B Models Beverage System Schematic -BC Models Operating Instructions Harvest Cycle Time Cam Switch ActionWiring Schematic SID 850/250 Wiring Diagram SID 850/250 208--230/115V, 1 PH, 60HZ Refrigeration Schematic Cleaning Instructions MaintenanceDispenser Section 90914 Troubleshooting Guide Start Does Unit OPERATE? No Operation of ANY Component 90914 NORMAL? ICE Maker Problem YES RUN RUN/STOP Stop Hopper YES Present AT No ICE on Evaporator Harvest YES Timer Dump Adjust ICE Thickness Probe only After ALL OTH LOW ICE Production 90914 Dispenser Problem YES Does 90914 BIN Thermostat MAINTENANCE/ADJUSTMENT ProceduresICE Thickness Adjustment Harvest Time Adjustment Harvest Timer Description Part Numbers Parts ListAir Cooled Water Cooled Refrigeration Components 250 250 BC Parts List CONT’DWarranty Remcor Incorporated Regency Drive Glendale Heights, IL 708