Cornelius UCR 700 Series service manual Semi-Annually, How Water Level Control Works, Purpose

Page 15

Semi–Annually

Semi-Annually in addition to all previously established service procedures perform the following:

1.Check for water leaks in tube connections, water fittings and lower Icemaker water seal.

2.Check drain tubes for clogs and aged tubes. Replace if tubes are stained or brittle.

3.Check for signs of condensation. Clean where necessary and replace insulation properly.

4.Check safety circuits for proper operation.

5.Check refrigeration system (see page 13).

6.Check unit for abnormal noise. Tighten machine and cabinet screws, if necessary.

7.Check white upper bearings on auger assembly. If bearings are less than 1/16￿ thick, replace. See Figure 4

REPLACE

OK

1/16￿

 

1/16￿

OK

REPLACE

FIGURE 4. UPPER NUT AND BEARING ASSEMBLY

WATER LEVEL CONTROL

How Water Level Control Works

When water is introduced through the inlet fitting the float rises. the float pushes against a lever which in turn forces the poppet assembly against the inlet fitting valve seat which seals the water off. See Figure 3 Before the water inlet is sealed the safety switch is operated. In the event of a water failure the float would drop down and operate the safety switch to shut off the machine.

If water level control will not shut off and seal at level as indicated, be sure inlet pressure does not exceed rec- ommended factory operating range.

Under ordinary circumstances adjustment should not be necessary providing it was properly adjusted when unit was installed or relocated. If, however, the control becomes inoperative, repair or replace. See Start-Up Adjust- ment, page 9.

Purpose

1.To automatically maintain proper water level in the evaporator when unit is running and making ice.

2.A safety switch is operated in the event of an interruption in water supply. The switch shuts off the electrical power to the icemaker and its refrigeration system. Switch will reset as soon as cause of water failure has been corrected and proper water level in icemaker has again been reached.

630460154

12

Image 15
Contents UCR 700 Series Continuous Flow Icemaker Table of Contents Table of Contents cont’d Follow Safety Instructions Safety InformationRecognize Safety Information Understand Signal WordsThis page Left Blank Intentionally Claims Instructions General DescriptionTo the User of this Manual DescriptionDesign Data cont’d Specification ChartClearance Requirements This page Left Blank Intentionally PRE-INSTALLATION InstallationSide Bracket Installation InstallationIcemaker Float Assembly Initial Start UP, Checks and Adjustment InstructionsThis page Left Blank Intentionally Monthly Guide to ServiceIcemaker Cleaning and Sanitizing Procedures MaintenancePurpose Water Level ControlSemi-Annually How Water Level Control WorksTo Replace Water Level Control Refrigeration System AdjustmentsTo Replace Water Level Safety Switch Refrigeration SystemAdjustment and Troubleshooting Expansion ValveCondenser Modulating Valve BIN Control Condenser Modulating Valve RemovalMotor Check GearmotorStart Relay To Replace Gearmotor AssemblyUpper NUT and Bearing Assembly Auger and Extruding Head RemovalTo Replace Bearing Capacitor Check Electrical CheckoutGear Motor Overload Safety ControlsGuide to Good ICE Wiring Diagram Troubleshooting Chart Icemaker not Operating Troubleshooting Compressors TroubleshootingParts List Name Panel ComponentsICE Chute Components Compressor Components Evaporator Components IMI Cornelius Certificate of WarrantyThis page Left Blank Intentionally IMI Cornelius INC