CLEANING THE ICE BIN
1.Prepare a mild detergent soap solution in 100)F potable water.
2.Using a nylon (not wire) bristle brush, clean the cold plate and the interior of the ice bin with the soap solu- tion.
3.Rinse the cold plate and interior bin surfaces with clean potable water.
4.Using a mechanical spray bottle, prepare a sanitizing solution according to the manufacturer’s directions and spray the entire interior bin surfaces. Allow to air dry.
CONNECTING PRODUCT TO THE DISPENSER
Note: All inlet connections are clearly marked with a label adjacent to the inlet connections.
Note: Always leak check all connections.
Note: A plumbing diagram when supplied with the unit, can be found in the dispensing tower.
PREPARING FOR OPERATION
On Units Without Electrically Operated Valves, Skip Steps 1 & 2 Below
1.Plug transformer into electrical outlet. The 24V supply must be connected in the dispensing tower.
2.Turn the 
3.Adjust the CO2 regulators as indicated in the following chart:
  | 
  | |||
  | 
  | 
  | 
  | |
  | Regulator | 
  | Pressure Setting | |
  | Primary (Carbonator)  | 
  | 90 – 120 PSI  | |
  | Secondary, Sugared Syrup Tank  | 55 PSI  | ||
  | Secondary, Diet Syrup Tank  | 
  | 8 – 12 PSI  | |
  | Secondary,   | 
  | 60 PSI  | |
  | 
  | 
  | ||
  | 
  | |||
  | Basic pressure shown is based on ambient temperature of 72)F. Use a  | |||
  | Cornelius   | |||
  | Basic Pressure  | 
  | 47 PSI  | |
  | For each 10 ft. of horizontal tubing  | Add 1 PSI  | ||
  | between tank and dispenser  | 
  | ||
  | For each 2 ft. of elevation  | 
  | Add 1 PSI  | |
  | For each tank per flavor over  | Add 1 PSI  | ||
  | 3 tanks  | 
  | 
  | |
4. Operate each valve until product is flowing.  | 
  | 
  | ||
EIMI Cornelius Inc;   | 5  | 10/4/94  | ||
Revised 10/8/03  | ||||
  | 
  | 
  | ||
166239001 Rev. Level 1