DSCover Satellite Products PC1555MX Cross Zone Police Reporting Code, Zone Restorals

Models: PC1555MX

1 52
Download 52 pages 39.34 Kb
Page 22
Image 22
Cross Zone Police Reporting Code
of minutes programmed for the AC Failure Communication Delay. The AC Failure Trouble Restoral reporting code follows the AC failure communication delay as well.
NOTE: If AC Failure Communications Delay is programmed as “000,” then the AC failure transmission will be immediate.
AC Failure Communication Delay . . . . . . . . . . . Section [370]
Wireless Maintenance
The panel will transmit a Wireless Device Low Battery Alarm reporting code if a low battery condition is indicated by a detector. The transmission of the trouble will be delayed by the number of days programmed for Zone Low Battery Transmission Delay. The Wireless Device Low Battery Resto- ral reporting code will be transmitted when the problem is cor- rected. The specific zone that caused the trouble will be recorded in the event buffer.
NOTE: The restoral will not be transmitted until all detectors indicate good battery conditions.
Wireless Maintenance Reporting Codes . . . . . Section [353] Wireless Device Battery Transmission Delay . . Section [370]
Arming and Activity Delinquency
When Delinquency Follows Arming (Days) is selected, the Delinquency reporting code is sent whenever the panel is not armed within the number of days programmed for the Delin- quency Transmission Cycle.
NOTE: If the Delinquency Transmission Cycle is set for one day, there must be 24 hours of no arming or disarming before the Delinquency Code will be sent. After a Delinquency Code has been transmitted, it will not be sent again until the system has been armed and disarmed.
When Delinquency Follows Zone Activity (hours) is enabled, if there is no activity on zones in the system, the Delinquency Transmission Cycle Timer in Section [370] will begin counting in hours. When the counter reaches the pro- grammed time, the panel will communicate the Delinquency reporting code to the central station, if programmed. If there is a closing or zone activity present on the system at any time, the counter will be reset.
NOTE: Activity Delinquency will not be reported while the panel is armed in Away mode.
NOTE: Activity on manually bypassed zones will not reset the timer.
NOTE: This timer is reset when the panel is armed, or if Installer Programming is entered.
NOTE: When using the SIA FSK communication format with Activity Delinquency, the Closing Delinquency identifier is transmitted.
Miscellaneous Maintenance Reporting Codes. Section [351] Delinquency Follows Zone Activity . . . . . . . . . . . . . .[380]: [8] Delinquency Transmission Cycle . . . . . . . . . . . . . . . . . . [370]
5.9 Communicator – Reporting Formats Each communication telephone number can be programmed to report using any one of five formats available. Two 20 BPS pulse formats are supported, in addition to Contact ID, SIA and Pager formats.

Reporting codes can be one or two digits and can use HEX digits (A through F). For a complete description of reporting codes which can be programmed and lists of automatic Con- tact ID and SIA format codes, please see Appendix A: “Reporting Codes” on page 42.

NOTE: Do not use the digit C in a reporting code when using Pager Format. In most cases, the digit C will be interpreted as a [#], which will terminate the page before it has finished.

Reporting Codes . . . . . . . . . . . . . . . . . Section [320] to [353]

Cross Zone Police Reporting Code

The Cross Zone Police Code Alarm will be sent when two different alarms occur during any armed-to-armed period. When an alarm occurs while the panel is armed and a second alarm occurs on a different zone during the same armed period, or after the system is disarmed, this code will be sent. All zone types contribute to this alarm. The cross zone police code will be transmitted immediately unless either or both zones have the Transmission Delay attribute enabled. If so, the code will be delayed for the programmed transmission delay time.

Cross Zone Police Code Alarm . . . . . . . . . . . . Section [328]

Zone Restorals

If the Restoral on Bell Time-outoption is selected, the panel will send the Zone Restoral Reporting Code for the zone if the bell cut-off time has expired and the zone is secured. If the zone is not secured when the bell cut-off time expires, the panel will send the restoral immediately once the zone is secured, or when the system is disarmed. If the Restoral on Bell Time-out option is not selected, the panel will immediately send the Zone Restoral Reporting Code when the zone is secured, regardless of whether or not the alarm output is active.

NOTE: 24 Hour type zones will report the restoral immediately when the zone is secured.

Restoral on Bell Time-out . . . . . . . . . . . . . . Section [380]: [2]

Closings (Arming Codes)

If the Closing Confirmation option is enabled, once the exit delay expires, the keypad will sound a series of eight beeps to confirm to the user that the closing code was sent and received by the central station.

Closing Confirmation . . . . . . . . . . . . . . . . . . Section [381]: [4]

Openings/Closings by Wireless Key

If you are using a PC5132 v3.0 or higher, wireless keys with access codes may be identified when they are used to arm or disarm the system: the panel will log and transmit opening or closing by access code (the same as if an access code had been used to arm/disarm the system). If wireless keys with no access code are used, the event will be logged and transmit- ted as opening or closing by keyswitch.

The Function Keys Require Code option must be selected (section [015], option 4 OFF) in order for wireless keys to be identified for arming. Disarming will always be logged by access code, if one is programmed for the Key, regardless of this option.

AC Failure Trouble Alarm Code

To prevent the panel from transmitting an AC Failure Trouble

Alarm reporting code during short power outages, the panel

will not send the signal unless AC power is lost for the amount

WWW.DIYALARMFORUM.COM

18

Page 22
Image 22
DSCover Satellite Products PC1555MX Cross Zone Police Reporting Code, Zone Restorals, Closings Arming Codes