![[015] Third System Option Code](/images/new-backgrounds/44394/4439471x1.webp)
[015] Third System Option Code |
|
|
| ||||
Default |
|
| Option | ON | Off | Section Page # | |
ON | I | I | 1 | Fire Keys Enabled | Fire Keys Disabled | 5.16 | 23 |
OFF | I | I | 2 | Panic Keys Audible (Bell / Beeps) | Panic Keys Silent | 5.16 | 23 |
OFF | I | I | 3 | Quick Exit Enabled | Quick Exit Disabled | 3.4 | 8 |
ON* | I | I | 4 | Quick Arming Enabled | Quick Arming Dis. / Function keys Req. Code 3.4 | 8 | |
OFF | I | I | 5 | Code Required For Bypassing | No Code Required | 3.4 | 8 |
OFF | I | I | 6 | Master Code Not Changeable | Master Code Changeable | 5.1 | 15 |
ON | I | I | 7 | TLM Enabled | TLM Disabled | 5.12 | 22 |
OFF | I | I | 8 | TLM Audible (Bell) When Armed | TLM Trouble Beeps When Armed | 5.12 | 22 |
* When using a PC5132 version 2.1 or older with WLS909 Wireless Keys, option [4] must be ON for the Arm button to work. |
| ||||||
[016] Fourth System Option Code |
|
|
| ||||
Default |
|
| Option | ON | Off | Section Page # | |
ON | I | I | 1 | AC Trouble Displayed | AC Trouble Not Displayed | 3.4 | 8 |
OFF | I | I | 2 | Trouble Light Flashes if AC Fails | Trouble Light Does Not Follow AC Status | 3.4 | 8 |
OFF | I | I | 3 | Blank Keypad When Not Used | Keypad Active Always | 5.22 | 25 |
OFF | I | I | 4 | Code Required to Remove Kypd BlankingNo Code Required | 5.22 | 25 | |
ON | I | I | 5 | Keypad Backlighting is enabled | Keypad Backlighting is disabled | 5.23 | 25 |
OFF | I | I | 6 | Power Save Mode enabled | Power Save Mode disabled | 5.22 | 25 |
OFF | I | I | 7 | Bypass Status Displayed While Armed | Bypass Status Not Displayed While Armed | 5.17 | 23 |
OFF | I | I | 8 | Keypad Tampers enabled | Keypad Tampers disabled | 5.25 | 25 |
[017] Fifth System Option Code |
|
|
| ||||
Default |
|
| Option | ON | Off | Section Page # | |
ON | I | I | 1 | WLS Key Does Not Use Access Codes* | WLS Key Uses Access Codes | 5.17 | 23 |
OFF | I | I | For Future Use |
|
|
| |
OFF | I | I | 8 | Squawk on Away Arming/Disarming OnlyBell Squawk on all Arming/Disarming | 5.17 | 23 |
*This option must be enabled when using a PC5132 v2.1 or earlier.
[020]Keypad Zone Assignments (Section 2.13 “Keypad Zones” on page 7)
NOTE: Only one keypad may be assigned to a zone.
Default
00 | I | I | I |
00 | I | I | I |
00 | I | I | I |
00 | I | I | I |
00 | I | I | I |
00 | I | I | I |
00 | I | I | I |
00 | I | I | I |
Keypad (slot 1) Zone | Valid entries are zones |
Keypad (slot 2) Zone | Valid entries are zones |
Keypad (slot 3) Zone | Valid entries are zones |
Keypad (slot 4) Zone | Valid entries are zones |
Keypad (slot 5) Zone | Valid entries are zones |
Keypad (slot 6) Zone | Valid entries are zones |
Keypad (slot 7) Zone | Valid entries are zones |
Keypad (slot 8) Zone | Valid entries are zones |
[030]Zone Loop Response Options
Default |
|
| Option | ON | Off | Section Page # | |
OFF | I | I | 1 | Zone 1 is Fast Loop Response | Zone 1 is Normal Loop Response | 5.24 | 25 |
OFF | I | I | 2 | Zone 2 is Fast Loop Response | Zone 2 is Normal Loop Response | 5.24 | 25 |
OFF | I | I | 3 | Zone 3 is Fast Loop Response | Zone 3 is Normal Loop Response | 5.24 | 25 |
OFF | I | I | 4 | Zone 4 is Fast Loop Response | Zone 4 is Normal Loop Response | 5.24 | 25 |
OFF | I | I | 5 | Zone 5 is Fast Loop Response | Zone 5 is Normal Loop Response | 5.24 | 25 |
OFF | I | I | 6 | Zone 6 is Fast Loop Response | Zone 6 is Normal Loop Response | 5.24 | 25 |
OFF | I | I | For future use |
|
|
|