DSCover Satellite Products PC1555MX installation manual Fifth User Display Mask

Models: PC1555MX

1 52
Download 52 pages 39.34 Kb
Page 50
Image 50
[67] Fifth User Display Mask

[67] Fifth User Display Mask

 

 

Default

 

 

Option

ON

OFF

OFF

I

I

1

Thermostat CTRL Prompt ON

Thermostat CTRL Prompt OFF

OFF

I

I

2

Temperature Setting Prompt ON

Temperature Setting Prompt OFF

OFF

I

I

3

Occupancy Mode Prompt ON

Occupancy Mode Prompt OFF

OFF

I

I

4

Thermostat Mode Prompt ON

Thermostat Mode Prompt OFF

OFF

I

I

5

Fan Control Prompt ON

Fan Control Prompt OFF

OFF

I

I

6

For Keypad View Prompt ON

For Keypad View Prompt OFF

OFF

I

I

7-8

For future use

 

[68] Sixth User Display Mask

 

 

Default

 

 

Option

ON

OFF

OFF

I

I

1

Occupancy Mode Auxiliary Prompt ON

Occupancy Mode Auxiliary Prompt OFF

OFF

I

I

2

Occupancy Mode Day Prompt ON

Occupancy Mode Day Prompt OFF

OFF

I

I

3

Occupancy Mode Away Prompt ON

Occupancy Mode Away Prompt OFF

OFF

I

I

4

Occupancy Mode Night Prompt ON

Occupancy Mode Night Prompt OFF

OFF

I

I

5-8

For future use

 

[97]View Software Version

[98]Initiate Global Label Broadcast

All LCD programming is done per keypad. If more than one LCD keypad are present on the system, and the PC5400 receives labels, labels pro- grammed at one keypad can be broadcast to all other LCD keypads. Perform the following procedure in order to broadcast labels:

Step 1 - Program one LCD keypad completely.

Step 2 - Make sure all LCD keypads are connected to the Keybus.

Step 3 - Enter Installer’s Programming, then enter Section [98] at the keypad that was programmed. The keypad will now broadcast all the informa- tion programmed to all the other LCD keypads on the system.

Step 4 - When the keypad is finished press the [#] key to exit.

[99] Reset LCD EEPROM to Factory Defaults

ASCII Characters

UL Listed Commercial and Residential Installations

The installation requirements listed below must be met for the follow-

Control of the Protected Premises

 

 

 

ing grades of service.

In order to have a UL Certificated system the protected area is to be

Grade A Local

under the responsibility of one ownership and management (i.e. one

business

under one name). This may

be a group of

buildings

The installation must have a bell UL Listed for mecantile local alarms

attached

or

unattached with different

addresses but

under

the

(AMSECO MBL10B with model AB-12 bell housing).

responsibility

of someone having mutual interest. The

person

of

The digital communicator must be enabled.

The control panel must be in the Attack Resistant Enclosure (DSC

mutual interest is not the alarm installing company.

 

 

Model CMC-1).

Bell Location

 

 

 

Swinger shutdown must be disabled.

The alarm sounding device (bell) must be located where it can be

Grade B Central Station and Police Connect

heard by the person or persons responsible for maintaining the secu-

rity system during the daily arming cycle.

 

 

 

The installation must have a bell UL Listed for mecantile local alarms

 

 

 

Protection of the Control Unit

 

 

 

(AMSECO MBL10B with model AB-12 bell housing).

 

 

 

The digital communicator must be enabled.

The local control and the local power supply must be protected by

Ringback must be enabled.

one of the following ways:

 

 

 

The control panel must be in the Attack Resistant Enclosure (DSC

• The control unit and audible alarm device power supply must be

Model CMC-1).

in a protected area which is armed 24 hours a day.

 

 

Swinger shutdown must be disabled.

• Each partition shall arm the area protecting the control unit and

Grade C Central Station

the audible alarm device power supply. This may require dupli-

cate protection armed by each partition. Access to this protected

The digital communicator must be enabled.

area, without causing an alarm, will require that all partitions be

Ringback must be enabled.

disarmed.

The control panel must be in the Attack Resistant Enclosure (DSC

Model CMC-1).

In all cases described above, the protected area for the control unit

Swinger shutdown must be disabled.

must be programmed as not bypassable.

Casual Users

All Commercial Installations

The installer should caution the user(s) to not give system information

• The entry delay must not exceed 60 seconds

to casual users (e.g. codes, bypass methods, etc. to baby-sitters or

• The exit delay must not exceed 60 seconds.

service people). Only the One-Time Use codes should be given to

• The minimum bell cutoff time is 15 minutes.

casual users.

Residential Installations

User Information

• The entry delay must not exceed 45 seconds

The installer should advise the users and note in the user instruction

• The exit delay must not exceed 60 seconds.

manual:

• The minimum bell cutoff time is 4 minutes.

• Service organization name and telephone number

Programming

• The programmed exit time

The notes in the programming sections describing the system config-

• The programmed entry time

urations for UL Listed installations must be implemented.

 

WWW.DIYALARMFORUM.COM

46

Page 50
Image 50
DSCover Satellite Products PC1555MX installation manual Fifth User Display Mask