[67] Fifth User Display Mask |
|
| |||
Default |
|
| Option | ON | OFF |
OFF | I | I | 1 | Thermostat CTRL Prompt ON | Thermostat CTRL Prompt OFF |
OFF | I | I | 2 | Temperature Setting Prompt ON | Temperature Setting Prompt OFF |
OFF | I | I | 3 | Occupancy Mode Prompt ON | Occupancy Mode Prompt OFF |
OFF | I | I | 4 | Thermostat Mode Prompt ON | Thermostat Mode Prompt OFF |
OFF | I | I | 5 | Fan Control Prompt ON | Fan Control Prompt OFF |
OFF | I | I | 6 | For Keypad View Prompt ON | For Keypad View Prompt OFF |
OFF | I | I | For future use |
| |
[68] Sixth User Display Mask |
|
| |||
Default |
|
| Option | ON | OFF |
OFF | I | I | 1 | Occupancy Mode Auxiliary Prompt ON | Occupancy Mode Auxiliary Prompt OFF |
OFF | I | I | 2 | Occupancy Mode Day Prompt ON | Occupancy Mode Day Prompt OFF |
OFF | I | I | 3 | Occupancy Mode Away Prompt ON | Occupancy Mode Away Prompt OFF |
OFF | I | I | 4 | Occupancy Mode Night Prompt ON | Occupancy Mode Night Prompt OFF |
OFF | I | I | For future use |
|
[97]View Software Version
[98]Initiate Global Label Broadcast
All LCD programming is done per keypad. If more than one LCD keypad are present on the system, and the PC5400 receives labels, labels pro- grammed at one keypad can be broadcast to all other LCD keypads. Perform the following procedure in order to broadcast labels:
Step 1 - Program one LCD keypad completely.
Step 2 - Make sure all LCD keypads are connected to the Keybus.
Step 3 - Enter Installer’s Programming, then enter Section [98] at the keypad that was programmed. The keypad will now broadcast all the informa- tion programmed to all the other LCD keypads on the system.
Step 4 - When the keypad is finished press the [#] key to exit.
[99] Reset LCD EEPROM to Factory Defaults
ASCII Characters
UL Listed Commercial and Residential Installations
The installation requirements listed below must be met for the follow- | Control of the Protected Premises |
|
|
| |||
ing grades of service. | In order to have a UL Certificated system the protected area is to be | ||||||
Grade A Local | under the responsibility of one ownership and management (i.e. one | ||||||
business | under one name). This may | be a group of | buildings | ||||
The installation must have a bell UL Listed for mecantile local alarms | |||||||
attached | or | unattached with different | addresses but | under | the | ||
(AMSECO MBL10B with model | |||||||
responsibility | of someone having mutual interest. The | person | of | ||||
The digital communicator must be enabled. | |||||||
The control panel must be in the Attack Resistant Enclosure (DSC | mutual interest is not the alarm installing company. |
|
| ||||
Model | Bell Location |
|
|
| |||
Swinger shutdown must be disabled. | The alarm sounding device (bell) must be located where it can be | ||||||
Grade B Central Station and Police Connect | heard by the person or persons responsible for maintaining the secu- | ||||||
rity system during the daily arming cycle. |
|
|
| ||||
The installation must have a bell UL Listed for mecantile local alarms |
|
|
| ||||
Protection of the Control Unit |
|
|
| ||||
(AMSECO MBL10B with model |
|
|
| ||||
The digital communicator must be enabled. | The local control and the local power supply must be protected by | ||||||
Ringback must be enabled. | one of the following ways: |
|
|
| |||
The control panel must be in the Attack Resistant Enclosure (DSC | • The control unit and audible alarm device power supply must be | ||||||
Model | in a protected area which is armed 24 hours a day. |
|
| ||||
Swinger shutdown must be disabled. | • Each partition shall arm the area protecting the control unit and |
Grade C Central Station | the audible alarm device power supply. This may require dupli- | |
cate protection armed by each partition. Access to this protected | ||
The digital communicator must be enabled. | ||
area, without causing an alarm, will require that all partitions be | ||
Ringback must be enabled. | ||
disarmed. | ||
The control panel must be in the Attack Resistant Enclosure (DSC | ||
Model | In all cases described above, the protected area for the control unit | |
Swinger shutdown must be disabled. | must be programmed as not bypassable. | |
Casual Users | ||
All Commercial Installations | ||
The installer should caution the user(s) to not give system information | ||
• The entry delay must not exceed 60 seconds | ||
to casual users (e.g. codes, bypass methods, etc. to | ||
• The exit delay must not exceed 60 seconds. | ||
service people). Only the | ||
• The minimum bell cutoff time is 15 minutes. | ||
casual users. | ||
Residential Installations | ||
User Information | ||
• The entry delay must not exceed 45 seconds | ||
The installer should advise the users and note in the user instruction | ||
• The exit delay must not exceed 60 seconds. | ||
manual: | ||
• The minimum bell cutoff time is 4 minutes. | ||
• Service organization name and telephone number | ||
Programming | ||
• The programmed exit time | ||
The notes in the programming sections describing the system config- | ||
• The programmed entry time | ||
urations for UL Listed installations must be implemented. | ||
| ||
WWW.DIYALARMFORUM.COM |
46