[348]Miscellaneous Opening (Disarming) Reporting Codes
(Section 5.8 “Communicator – Reporting Codes” on pg. 17, & Appendix A)
I I I
I I I
I I I
I I I
1.Opening by Duress Code 33
2.Opening by Duress Code 34
3.Opening by Master Code 40
4.Opening by Supervisory Code 41
I I I
I I I
I I I
5.Opening by Supervisory Code 42
6.Auto Arm Cancellation
7.Special Opening
[349]Maintenance Alarm Reporting Codes (Section 5.8 “Communicator – Reporting Codes” on pg. 17, & Appendix A)
I | I | I | 1. | Battery Trouble Alarm | I | I | I | 5. | Auxiliary Power Supply Trouble Alarm |
I | I | I | 2. | AC Failure Trouble Alarm | I | I | I | 6. | TLM Trouble Code (via LINKS) |
I | I | I | 3. | Bell Circuit Trouble Alarm | I | I | I | 7.General System Trouble | |
I | I | I | 4. | Fire Trouble Alarm | I | I | I | 8. | General System Supervisory |
[350]Maintenance Restoral Reporting Codes (Section 5.8 “Communicator – Reporting Codes” on pg. 17, & Appendix A)
I | I | I | 1. | Battery Trouble Restoral | I | I | I | 5. | Auxiliary Power Supply Trouble Restoral |
I | I | I | 2. | AC Failure Trouble Restoral | I | I | I | 6. | TLM Restoral |
I | I | I | 3. | Bell Circuit Trouble Restoral | I | I | I | 7. | General System Trouble Restore |
I | I | I | 4. | Fire Trouble Restoral | I | I | I | 8. | General System Supervisory Restore |
[351]Miscellaneous Maintenance Reporting Codes (Section 5.8 “Communicator – Reporting Codes” on pg. 17, & Appendix A)
I | I | I | 1. | Telephone Number 1 FTC Restore | I | I | I 5. DLS Lead OUT | ||
I | I | I | 2. | Telephone Number 2 FTC Restore | I | I | I | 6. | Zone Fault Alarm |
I | I | I | 3. | Event Buffer 75% Full Since Last Upload I | I | I | 7. | Zone Fault Restore | |
I | I | I | 4. | DLS Lead IN | I | I | I | 8. | Delinquency Code |
[352]Test Transmission Reporting Codes (Section 5.8 “Communicator – Reporting Codes” on pg. 17, & Appendix A)
I | I | I | 1. | Periodic Test Transmission | I I I 3. LINKS1000 Test Transmission Code* |
I | I | I | 2. | System Test |
|
*The LINKS Test Transmission Code must be programmed as “00” for the LINKS Test Transmission to be disabled.
[353]Wireless Maintenance Reporting Codes (Section 5.8 “Communicator – Reporting Codes” on pg. 17, & Appendix A)
I I I | 1. Wireless Device Low Battery Alarm | I I I 2. Wireless Device Low Battery Restore |
[360]Communicator Format Options (Section 5.9 “Communicator – Reporting Formats” on page 18)
NOTE: The Third telephone number follows the format of the First telephone number.
Default
02
02
I I I
I I I
1st/3rd Telephone Number
2nd Telephone Number
01 20 BPS, 1400 HZ handshake | 04 | SIA FSK |
02 20 BPS, 2300 HZ handshake | 05 | Pager |
03DTMF CONTACT ID
[361]Alarm/Restore Communicator Call Directions (Section 5.5 “Communicator – Dialing” on page 17)
Default |
|
| Option | ON | OFF |
ON | I | I | 1 | 1st Telephone Number | Disabled |
OFF | I | I | 2 | 2nd Telephone Number | Disabled |
OFF | I | I | 3 | 1st Telephone Number (via LINKS) | Disabled |
OFF | I | I | 4 | 2nd Telephone Number (via LINKS) | Disabled |
OFF | I | I | For future use |
|
[363]Tamper/Restore Communicator Call Directions (Section 5.5 “Communicator – Dialing” on page 17)
Default |
|
| Option | ON | OFF |
ON | I | I | 1 | 1st Telephone Number | Disabled |
OFF | I | I | 2 | 2nd Telephone Number | Disabled |
OFF | I | I | 3 | 1st Telephone Number (via LINKS) | Disabled |
OFF | I | I | 4 | 2nd Telephone Number (via LINKS) | Disabled |
OFF | I | I | For future use |
|
WWW.DIYALARMFORUM.COM
38