Section 1: System Introduction
1.1 | Specifications | Digital Communicator Specifications* |
| |||||||||
Downloading Software Support | • Supports major communication formats including SIA and | |||||||||||
| Contact ID |
|
|
|
|
| ||||||
• PC1555MX v2.3 uses |
|
|
|
|
|
| ||||||
• Digital Communicator compatible receivers and their formats: | ||||||||||||
Flexible Zone Configuration | ||||||||||||
| Silent Knight Model 9000: 3/1, 4/1, 4/2 | |||||||||||
• Six fully programmable zones |
| |||||||||||
| extended, 20 bps, 1400 Hz handshake. |
|
| |||||||||
• System expandable to 32 zones using: |
|
|
| |||||||||
| Ademco | Model | 685: 3/1, | 4/1, | 4/2 | 3/1 | ||||||
| • up to 8 keypad zone inputs and/or |
| ||||||||||
|
| extended, 20 bps, 1400 Hz handshake, Contact ID. |
| |||||||||
| • | up to 32 wireless | zones with the PC5132 wireless |
|
| |||||||
|
| Sescoa Model 3000: 3/1, | 4/1, | 4/2 | 3/1 | |||||||
|
| expansion module |
|
| ||||||||
|
|
|
| extended, 20 bps, 1400 Hz handshake. |
|
| ||||||
• | 38 | access codes: one | master code, one maintenance |
|
|
| ||||||
| Radionics | Model | D6500: | 3/1, | 4/2 | 3/1 | ||||||
| code, two duress codes, two supervision codes and 32 |
| ||||||||||
|
| extended, with or without parity, 1400 and 2300 Hz hand- | ||||||||||
| general access codes |
|
| |||||||||
|
|
| ||||||||||
• 27 zone types; 8 programmable zone attributes |
| |||||||||||
| 20 bps, 1400 and 2300 Hz handshake, Contact ID, SIA. |
| ||||||||||
• Normally closed, single EOL and double EOL zone wiring | • |
|
|
| ||||||||
• 32 wireless zones with the PC5132 Wireless Receiver | • Three programmable telephone numbers |
| ||||||||||
Audible Alarm Output |
| • | Two account numbers |
|
|
|
| |||||
• 700mA Supervised Bell Output (current limited at 3A), 12VDC | • Supports LINKS1000 cellular communication |
| ||||||||||
• Steady or Pulsed Output |
| • Supports LINKS2X50 long range radio transmitter |
| |||||||||
EEPROM Memory |
| • | Supports Skyroute transceiver |
|
|
| ||||||
• Does not lose programming or system status on complete | • DTMF and pulse dialing |
|
|
|
| |||||||
| AC and Battery failure |
| • | DPDT line seizure |
|
|
|
|
| |||
Programmable Outputs | • |
|
|
|
|
| ||||||
• Split reporting of selected transmissions to each telephone | ||||||||||||
• One programmable voltage output and one programmable | ||||||||||||
| number |
|
|
|
|
|
| |||||
| voltage output/input; 23 programmable options |
|
|
|
|
|
|
| ||||
| System Supervision Features |
|
|
| ||||||||
• PGM1 = 50mA; PGM2 = 300mA (50/300 products) |
|
|
| |||||||||
• PGM2 = 50mA; PGM2 = 50mA (50/50 products) | The PC1555MX continuously monitors a number of possible | |||||||||||
• Eight additional low current (50mA) outputs available using | trouble conditions including: |
|
|
|
| |||||||
| the PC5208 module |
| • | AC power failure |
| • AUX Power Supply Trouble | ||||||
• | Four additional high current (300mA) outputs available | • | Fault by zone |
| • Loss of internal clock |
| ||||||
| using the PC5204 module; one PC5204 output fully super- | • | Tamper by zone |
| • Bell output trouble |
| ||||||
| vised for siren |
| • | Fire trouble |
| • Telephone line trouble |
| |||||
Powerful 1.5 Amp Regulated Power Supply | • | Failure to communicate | • Low battery condition (panel) | |||||||||
• 550 mA Auxiliary Supply, 12 VDC | • Low battery by zone (wireless) |
|
|
| ||||||||
• Positive Temperature | Coefficient (PTC) components | • Module fault (supervisory or tamper) |
|
| ||||||||
| replace fuses |
| False Alarm Prevention Features |
|
| |||||||
• Supervision for loss of AC power, low battery | • | Audible Exit Delay | • Quick Exit |
| ||||||||
• Internal clock locked to AC power frequency | • | Audible Exit Fault |
| • Cross Zone Burglary Alarm | ||||||||
Power Requirements |
| • | Communication Delay | • Rotating Keypress Buffer |
| |||||||
• Transformer = 16.5 VAC, 40VA | • | Urgency on Entry Delay | • One Restart of Exit Delay |
| ||||||||
• Battery = 12 volt 4 Ah minimum rechargeable sealed lead | Additional Features |
|
|
|
| |||||||
| acid battery |
| • Auto Arm at specified time |
|
|
|
| |||||
• For household fire and burglary installations, two 7Ah bat- | • |
| ||||||||||
| teries in parallel must | be used, providing 24 hours of | • All modules connect to the system via a four wire Keybus | |||||||||
| standby power and 4 minutes of alarm output power. | |||||||||||
|
| up to 1000’/305m from main panel |
|
|
| |||||||
• For commercial burglary installations, a 4Ah (or larger) bat- |
|
|
|
| ||||||||
• | An event buffer which records the past 128 events with | |||||||||||
| tery must be used, providing at least 4 hours of standby | |||||||||||
|
| both the time and date at which they occurred; buffer can | ||||||||||
| power and 4 minutes of alarm output power. |
| ||||||||||
|
| be printed using PC5400 serial interface module, or | ||||||||||
WARNING: Do not install this panel outside of North America. |
| |||||||||||
| viewed with the LCD5500Z keypad and |
| ||||||||||
By design, this panel will not work if the AC line frequency | • Supports the addition of the PC5132 wireless receiver for | |||||||||||
drops below 55.5Hz. |
|
| integration of wireless devices |
|
|
| ||||||
Remote Keypad Specifications | • Uploading and downloading capability |
|
| |||||||||
• | Keypads available: |
| • | Local downloading capability through the use of | the | |||||||
| - PC5508Z eight zone LED keypad with zone input |
|
|
|
|
|
| |||||
| - PC5516Z sixteen zone LED keypad with zone input | • Supports the Escort5580 Voice Prompt Module with auto- | ||||||||||
| - PC5532Z |
| mation/lighting control |
|
|
|
| |||||
| - LCD5500Z Alphanumeric keypad with zone input | • Supports the addition of the PC5928 Audio Interface Mod- | ||||||||||
| - LCD5501Z fixed message LCD keypad with zone input |
| ule to integrate intercom stations |
|
|
| ||||||
| - | • | Added Keybus fault protection: clock and data outputs | |||||||||
• All keypads have five programmable function keys |
| have been programmed to withstand shorts to +12v to pre- | ||||||||||
• Connect up to eight keypads |
| vent control panel damage |
|
|
|
| ||||||
• |
|
|
|
|
|
|
|
|
• Built in piezoelectric buzzer |
|
*LINKS1000, LINKS2X50, and SkyrouteWWW.DIYALARMFORUM.COMhave not been investigated by UL. | 1 |
|