DSCover Satellite Products PC1555MX Appendix A Reporting Codes, Contact ID, Burg - Entry/Exit

Models: PC1555MX

1 52
Download 52 pages 39.34 Kb
Page 46
Image 46
Appendix A: Reporting Codes

Appendix A: Reporting Codes

The following tables contain Contact ID and Automatic SIA for- mat reporting codes. For more information on reporting code formats and notes about individual reporting codes, see sec- tions 5.8 “Communicator – Reporting Codes” on page 17 and

5.9“Communicator – Reporting Formats” on page 18.

Contact ID

The first digit (in parentheses) will automatically be sent by the control. The second two digits are programmed to indicate spe- cific information about the signal.

For example, if zone 1 is an entry/exit point, you could program the event code as [34]. The central station would receive the following:

*BURG - ENTRY/EXIT - 1

where the “1” indicates which zone went into alarm.

SIA Format - Level 2 (Hardcoded)

The SIA communication format used in this product follows the level 2 specifications of the SIA Digital Communication Stan- dard - January 1996. This format will send the Account Code along with its data transmission. The transmission would look similar to the following at the receiver:

N Ri01

 

BA 01

N

=

New Event

Ri01

=

Partition /Area Identifier

BA

=

Burglary Alarm

01

=

Zone 1

 

 

 

Dialer

Automatic

SIA Auto Rep

Section #

Reporting Code

Code Sent When...

Contact ID

Direction*

Codes**

 

 

 

Codes

 

 

 

 

 

 

 

 

 

 

 

[320]

Zone Alarms

zone goes into alarm

A/R

(1) 3A

See Table 3

 

 

 

 

 

 

[324]

Zone Restorals

alarm condition has been restored

A/R

(1) 3A

 

 

 

 

 

 

 

[330]

Zone Tamper/Restoral

zone exhibits a tamper condition/tamper condition

T/R

(1) 44

TA-ZZ/TR-ZZ

[334]

 

restored

 

 

 

 

 

 

 

 

 

[328]

Duress Alarm

duress code entered at keypad

A/R

(1) 21

HA-00

 

 

 

 

 

 

[328]

Opening After Alarm

system disarmed with alarm in memory

A/R

(4) A6

OR-00

 

 

 

 

 

 

[328]

Recent Closing

alarm occurs within two minutes of system arming

A/R

(4) 59

CR-00

[328]

Zone Expander Supervi-

panel loses/restores supervisory transmission over the

A/R

(1) 43

UA-00/UH-00

 

sory Alarm/Rest.

Keybus from enrolled PC5132 module or keypads with

 

 

 

 

 

zone inputs

 

 

 

 

 

 

 

 

 

[328]

Cross Zone (Police Code)

two zones on the same partition go into alarm during

A/R

(1) 4A

BV-00

 

Alarm

any given armed-to-armed period (incl. 24Hr zones)

 

 

 

 

 

 

 

 

 

[329]

[F] Key Alarm/Rest.

Keypad fire alarm (alarm and restore rep. codes sent

A/R

(1) 15

FA-00/FH-00

 

 

together)

 

 

 

 

 

 

 

 

 

[329]

[A] Key Alarm/Rest.

Keypad auxiliary alarm (alarm and restore rep. codes

A/R

(1) AA

MA-00/MH-00

 

 

sent together)

 

 

 

 

 

 

 

 

 

[329]

[P] Key Alarm/Rest.

Keypad panic alarm (alarm and restore rep. codes sent

A/R

(1) 2A

PA-00/PH-00

 

 

together)

 

 

 

 

 

 

 

 

 

[329]

PGM2 Alarm/Rest.

a panic button wired to PGM2 is pressed / access code

A/R

(1) 4A

UA-99/UH-99

 

 

is entered (PGM2 programmed as option [23] or [24])

 

 

 

 

 

 

 

 

 

 

 

a 2-wire smoke detector wired to PGM2 goes into alarm/

A/R

(1) 11

FA-99/FH-99

 

 

alarm is cleared (PGM2 programmed as option [04])

 

 

 

 

 

 

 

 

 

[338]

General System Tamper/

enrolled module with tamper inputs has a tamper alarm/

T/R

(1) 45

TA-00/TR-00

 

Rest.

all module tampers restored

 

 

 

 

 

 

 

 

 

[338]

Keypad Lockout

max. number of incorrect access codes has been

T/R

(4) 21

JA-00

 

 

entered at a keypad

 

 

 

 

 

 

 

 

 

[339-343]

Closings

system armed (user 01-34, 40-42 indicated)

O/C

(4) A2

CL-UU

 

 

 

 

 

 

[343]

Partial Closing

one or more zones bypassed when system armed

O/C

(4) 7A

CG-ZZ

 

 

 

 

 

 

[343]

Special Closing

Closing (arming) using one of the following methods:

O/C

(4) AA

CL-00

 

 

quick arm, auto arm, keyswitch, function key, mainte-

 

 

 

 

 

nance code, DLS software

 

 

 

 

 

 

 

 

 

[344-348]

Openings

system disarmed (user 01-34, 40-42 indicated)

O/C

(4) A2

OP-UU

 

 

 

 

 

 

[348]

Auto Arm Cancellation

auto arm cancelled

O/C

(4) A5

CE-00

 

 

 

 

 

 

[348]

Special Opening

Opening (disarming) using one of the following meth-

O/C

(4) AA

OP-00

 

 

ods: keyswitch, maintenance code, DLS software

 

 

 

 

 

 

 

 

 

[349-350]

Battery Trouble/Rest.

PC1555MX battery is low/battery restored

MA/R

(3) A2

YT-00/YR-00

 

 

 

 

 

 

* A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions ** UU = user number (user01-42); ZZ = zone number (01-32)

WWW.DIYALARMFORUM.COM

42

Page 46
Image 46
DSCover Satellite Products PC1555MX installation manual Appendix A Reporting Codes, Contact ID, Burg - Entry/Exit