Appendix A: Reporting Codes
The following tables contain Contact ID and Automatic SIA for- mat reporting codes. For more information on reporting code formats and notes about individual reporting codes, see sec- tions 5.8 “Communicator – Reporting Codes” on page 17 and
5.9“Communicator – Reporting Formats” on page 18.
Contact ID
The first digit (in parentheses) will automatically be sent by the control. The second two digits are programmed to indicate spe- cific information about the signal.
For example, if zone 1 is an entry/exit point, you could program the event code as [34]. The central station would receive the following:
*BURG - ENTRY/EXIT - 1
where the “1” indicates which zone went into alarm.
SIA Format - Level 2 (Hardcoded)
The SIA communication format used in this product follows the level 2 specifications of the SIA Digital Communication Stan- dard - January 1996. This format will send the Account Code along with its data transmission. The transmission would look similar to the following at the receiver:
N Ri01 |
| BA 01 |
N | = | New Event |
Ri01 | = | Partition /Area Identifier |
BA | = | Burglary Alarm |
01 | = | Zone 1 |
|
|
| Dialer | Automatic | SIA Auto Rep | |
Section # | Reporting Code | Code Sent When... | Contact ID | |||
Direction* | Codes** | |||||
|
|
| Codes | |||
|
|
|
|
| ||
|
|
|
|
|
| |
[320] | Zone Alarms | zone goes into alarm | A/R | (1) 3A | See Table 3 | |
|
|
|
|
|
| |
[324] | Zone Restorals | alarm condition has been restored | A/R | (1) 3A |
| |
|
|
|
|
|
| |
[330] | Zone Tamper/Restoral | zone exhibits a tamper condition/tamper condition | T/R | (1) 44 | ||
[334] |
| restored |
|
|
| |
|
|
|
|
|
| |
[328] | Duress Alarm | duress code entered at keypad | A/R | (1) 21 | ||
|
|
|
|
|
| |
[328] | Opening After Alarm | system disarmed with alarm in memory | A/R | (4) A6 | ||
|
|
|
|
|
| |
[328] | Recent Closing | alarm occurs within two minutes of system arming | A/R | (4) 59 | ||
[328] | Zone Expander Supervi- | panel loses/restores supervisory transmission over the | A/R | (1) 43 | ||
| sory Alarm/Rest. | Keybus from enrolled PC5132 module or keypads with |
|
|
| |
|
| zone inputs |
|
|
| |
|
|
|
|
|
| |
[328] | Cross Zone (Police Code) | two zones on the same partition go into alarm during | A/R | (1) 4A | ||
| Alarm | any given |
|
|
| |
|
|
|
|
|
| |
[329] | [F] Key Alarm/Rest. | Keypad fire alarm (alarm and restore rep. codes sent | A/R | (1) 15 | ||
|
| together) |
|
|
| |
|
|
|
|
|
| |
[329] | [A] Key Alarm/Rest. | Keypad auxiliary alarm (alarm and restore rep. codes | A/R | (1) AA | ||
|
| sent together) |
|
|
| |
|
|
|
|
|
| |
[329] | [P] Key Alarm/Rest. | Keypad panic alarm (alarm and restore rep. codes sent | A/R | (1) 2A | ||
|
| together) |
|
|
| |
|
|
|
|
|
| |
[329] | PGM2 Alarm/Rest. | a panic button wired to PGM2 is pressed / access code | A/R | (1) 4A | ||
|
| is entered (PGM2 programmed as option [23] or [24]) |
|
|
| |
|
|
|
|
|
| |
|
| a | A/R | (1) 11 | ||
|
| alarm is cleared (PGM2 programmed as option [04]) |
|
|
| |
|
|
|
|
|
| |
[338] | General System Tamper/ | enrolled module with tamper inputs has a tamper alarm/ | T/R | (1) 45 | ||
| Rest. | all module tampers restored |
|
|
| |
|
|
|
|
|
| |
[338] | Keypad Lockout | max. number of incorrect access codes has been | T/R | (4) 21 | ||
|
| entered at a keypad |
|
|
| |
|
|
|
|
|
| |
Closings | system armed (user | O/C | (4) A2 | |||
|
|
|
|
|
| |
[343] | Partial Closing | one or more zones bypassed when system armed | O/C | (4) 7A | ||
|
|
|
|
|
| |
[343] | Special Closing | Closing (arming) using one of the following methods: | O/C | (4) AA | ||
|
| quick arm, auto arm, keyswitch, function key, mainte- |
|
|
| |
|
| nance code, DLS software |
|
|
| |
|
|
|
|
|
| |
Openings | system disarmed (user | O/C | (4) A2 | |||
|
|
|
|
|
| |
[348] | Auto Arm Cancellation | auto arm cancelled | O/C | (4) A5 | ||
|
|
|
|
|
| |
[348] | Special Opening | Opening (disarming) using one of the following meth- | O/C | (4) AA | ||
|
| ods: keyswitch, maintenance code, DLS software |
|
|
| |
|
|
|
|
|
| |
Battery Trouble/Rest. | PC1555MX battery is low/battery restored | MA/R | (3) A2 | |||
|
|
|
|
|
|
* A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions ** UU = user number
WWW.DIYALARMFORUM.COM