P r o g r a m m i n g W o r k s h e e t s
[010]PC5208 PGM Output Programming (PGM
Default |
| Default |
|
01 | I I I PGM 3 | 01 | I I I PGM 7 |
01
01
01
I I I
I I I
I I I
PGM 4 | 01 |
PGM 5 | 01 |
PGM 6 | 01 |
I I I
I I I
I I I
PGM 8
PGM 9
PGM 10
Program PGM Option Attributes in sections [143] - [150].
[011]PC5204 PGM Output Programming (PGM
Default |
|
|
|
| Default |
|
|
|
|
01 | I | I | I | PGM 11 | 01 | I | I | I | PGM 13 |
01 | I | I | I | PGM 12 | 01 | I | I | I | PGM 14 |
Program PGM Option Attributes in sections [151] - [154].
[012]Keypad Lockout Options (Section 5.21 “Keypad Lockout Options” on page 24)
NOTE: If Keypad Lockout is active, the panel cannot be disarmed with a keyswitch.
Default
000
000
I I I I
I I I I
Number of Invalid Codes Before Lockout
[013] First System Option Code |
|
|
| ||||
Default |
|
| Option | ON | Off | Section Page # | |
OFF | I | I | 1 | Normally Closed Loops | 2.9 | 5 | |
OFF | I | I | 2 | Double | Single | 2.9 | 5 |
ON* | I | I | 3 | Panel shows all troubles when armed | Panel shows only Fire troubles when armed | 3.4 | 8 |
OFF | I | I | 4 | Tampers/Faults do not show as open | Tampers/Faults show as open | 3.4 | 8 |
OFF | I | I | 5 | For future use |
|
|
|
ON | I | I | 6 | Audible Exit Fault Enabled | Audible Exit Fault Disabled | 5.18 | 24 |
ON | I | I | 7 | Event Buffer Follows Swinger Shutdown Event Buffer Logs Events Past shutdown | 5.20 | 24 | |
OFF | I | I | 8 | Temporal Three Fire Signal Enabled** | Standard Pulsed Fire Signal | 5.13 | 22 |
* Option 3 must be OFF if LCD keypads older than v2.0 are used. |
|
|
| ||||
**The Temporal Three Fire Signal option must be used for UL Household Fire installations. |
|
| |||||
[014] Second System Option Code |
|
|
| ||||
Default |
|
| Option | ON | Off | Section | Page # |
OFF | I | I | 1 | Arm / Disarm Bell Squawk enabled | Arm / Disarm Bell Squawk disabled | 5.17 | 23 |
OFF | I | I | 2 | Bell Squawk During Auto Arm | No Bell Squawk During Auto Arm | 5.18 | 24 |
OFF | I | I | 3 | Bell Squawk On Exit Delay | No Bell Squawk On Exit Delay | 5.18 | 24 |
OFF | I | I | 4 | Bell Squawk On Entry Delay | No Bell Squawk On Entry Delay | 5.18 | 24 |
OFF | I | I | 5 | Bell Squawk On Trouble | No Bell Squawk On Trouble | 3.4 | 8 |
ON | I | I | 6 | Audible Exit with Urgency | Silent Exit Delay | 5.18 | 24 |
OFF | I | I | 7 | Exit Delay Termination Enabled | Exit Delay Termination Disabled | 5.18 | 24 |
OFF | I | I | 8 | Fire Bell is Continuous | Fire Bell Follows Bell | 5.13 | 22 |