Lucent Technologies Network Access Module manual Current Events, Selected Interval Events

Models: Network Access Module

1 75
Download 75 pages 54.1 Kb
Page 65
Image 65

INA Module Maintenance Options

Each error statistic represents the sum of error events from all valid intervals including the current interval. The message “9999” represents an overflow situation.

You can refresh the 24-hour total screen by pressing Back and then pressing 24 hr total again.

Current Events

The Current error event screen reports error statistics for the 15-minute interval that is currently active. The elapsed minutes line displays the number of minutes that have elapsed for the current interval. The elapsed minutes display ranges from 0 to 15 and is rounded to the nearest minute. From your system programming console, use the following sequence to access the Current screen. Be sure to select the corresponding INA module slot number.

Menu: MaintenanceSlotSlot#EnterError EventsCurrent

The events reported are the same as for the 24 hour event totals screen.

You can refresh the Current screen by pressing Back and then pressing Current again.

￿Selected Interval Events

The Selected Interval Events screen reports on error statistics for a specific 15-minute interval from the past 24 hours. Ninety-six 15-minute intervals occur in a 24-hour period. Interval 1 is the most recent 15 minute interval just before the current interval, and interval 96 is the oldest interval. From your system programming console, use the following sequence to select a specific interval from the Selected Interval Events screen. Be sure to select the corresponding INA module slot number.

Menu: MaintenanceSlotSlot#EnterErrorEventsInterval

Interval#Enter

Note – Invalid intervals have all zeroes for error data, but no visual indication is given to show that the interval is not valid. You can, however, compute the total number of invalid intervals by subtracting the valid interval count on the 24-hour total screen from 96.

Clearing Error Events

The Clear Error Events screen causes error events for all intervals, including the current interval, to be cleared. From your system programming console, use the following sequence to access the Clear Error Events screen. Be sure to select the corresponding INA module slot number.

Menu: MaintenanceSlotSlot#EnterError EventsClear

To stop the clear event and retain all error events, press Back or Cancel. You will return to the Error events screen.

C-5

Page 65
Image 65
Lucent Technologies Network Access Module manual Current Events, Selected Interval Events, Clearing Error Events