INA Module System Interactions
Board Renumbering
The INA module works in the same manner as the 100D module for board renumbering. Use board renumbering to replace a 100D module with a 100R module, and vice versa. After the board renumbering, T1/PRI data that had been previously administered for the replaced module is associated with the new module. The data channels assigned to the 100R are now be unassigned on the 100D module.
Print Reports
The System Inventory Report is enhanced to include summary information about INA modules present in the system. This summary information is presented under the
PCMCIA Flash Memory Card-Based Upgrade Operation
The INA module firmware is upgradeable using the MERLIN MAGIX PCMCIA card.
Note – Performing an upgrade to the INA module firmware using the MERLIN MAGIX PCMCIA card does not upgrade the INA module router software. Router software is upgraded separately with the PMVision application. Depending upon the nature of the upgrade, either a INA module firmware upgrade, or a router software upgrade, or both might be required.
Other System Interactions
Table
Table
ConditionExplanation
Idle Conditions - The system might be forced into an idle state
System Forced while the module is routing data traffic. When
Idlethe system is in the forced idle condition, the router on the INA module continues to operate and route data traffic.
Slot
INA Module Installation and Configuration Guide |