Using the DS-1 Test Jacks

Table A-3DS-1 Test Jacks Description

Test Jack Label

Description and Usage

 

 

MON In

Monitor In. This jack allows external test equipment to

 

passively monitor the T1/PRI signal coming from the

 

network to the INA module. The use of this jack does not

 

disrupt the T1/PRI signal received by the INA module from

 

the network.

MON Out

Monitor Out. This jack allows external test equipment to

 

passively monitor the T1/PRI signal going to the network

 

from the INA module. The use of this jack does not disrupt

 

the T1/PRI signal transmitted by the INA module to the

 

network.

NET In

Network In. An intrusive, break-in jack that allows external

 

test equipment to inject a T1/PRI signal to the network. The

 

use of this jack disrupts the T1/PRI signal transmitted by the

 

INA module to the network.

EQPT Out

Equipment Out. An intrusive, break-in jack that allows

 

external test equipment to intercept and terminate the

 

T1/PRI signal coming from the INA module. The use of this

 

jack disrupts the T1/PRI signal transmitted by the INA

 

module to the network.

NET Out

Network Out. An intrusive, break-in jack that allows

 

external test equipment to intercept and terminate the

 

T1/PRI signal coming from the network. The use of this jack

 

disrupts the T1/PRI signal received by the INA module from

 

the network.

EQPT In

Equipment In. An intrusive, break-in jack that allows

 

external test equipment to inject a T1/PRI signal to the INA

 

module. The use of this jack disrupts the T1/PRI signal

 

received by the INA module from the network.

 

 