Using the DS-1 Test Jacks

 

 

Table A-2Interpreting Diagnostic Boot Messages (Continued)

 

 

 

 

 

 

 

Field

Possible Message

Explanation

 

 

 

 

 

 

 

Setting up ACC 2188 PCI Controller

 

PCI memory has been

 

 

Found 16384K PCI Memory at 0x1ffff000

 

correctly set up.

 

 

Testing PCI Memory block 0x20000000-

 

 

 

 

0x20ffffff ...Passed

 

 

 

 

Total of 16384K PCI Memory Ready

 

 

 

 

block alloc 425 870400

 

 

 

 

block_alloc: cpu<0> control 0028bdb0

 

 

 

 

free_count<425>

 

 

 

 

PM3VT/Legend ComOS V4.15.a4.

 

ComOS version string.

 

 

100R HV=01 FBV=00 FAV=11 FAS=01

 

MERLIN firmware

 

 

 

 

identification.

 

 

Found x ports

3

Number of ports found,

 

 

 

 

including C0 and C1.

 

 

Ether0 active

PCI-Master

Ethernet interface found.

 

 

Running ComOS

N/A

If the system becomes

 

 

 

 

suspended at this point

 

 

 

 

and does not print the next

 

 

 

 

message, the configuration

 

 

 

 

nonvolatile RAM

 

 

 

 

(NVRAM) has been

 

 

 

 

corrupted. Refer to the

 

 

 

 

PortMaster Troubleshooting

 

 

 

 

Guide for instructions on

 

 

 

 

nonvolatile RAM recovery.

 

 

PortMaster Console login:

N/A

System is up and running.

 

 

 

 

 

 

Using the DS-1 Test Jacks

The six test jacks provide the means to connect external test equipment to the T1/PRI line. Table A-3describes the functions of the individual jacks. Figure A-1illustrates the test jack locations. Figure A-2shows the test jack configuration.