| Dialer | Automatic | SIA Auto Rep | |
Section # | Reporting Code | Code Sent When... | Contact ID | |||
Direction* | Codes** | |||||
|
|
| Codes | |||
|
|
|
|
| ||
|
|
|
|
|
| |
AC Line Trouble/Rest. | AC power to control panel is disconnected or inter- | MA/R | (3) A1 | |||
|
| rupted/AC power restored (Both codes follow AC Fail- |
|
|
| |
|
| ure Comm. Delay.) |
|
|
| |
|
|
|
|
|
| |
Main Bell Trouble/Rest. | open circuit detected across bell terminals/bell circuit | MA/R | (3) 21 | |||
|
| closed |
|
|
| |
|
|
|
|
|
| |
Fire Trouble/Rest. | a trouble occurs/restores on a fire zone | MA/R | (3) 73 | |||
|
|
|
|
|
| |
Auxiliary Power Trouble/ | aux voltage supply trouble/restoral | MA/R | (3) AA | |||
| Rest. |
|
|
|
| |
[349] | TLM Failure | telephone line monitoring trouble (sent via LINKS. Do | MA/R | (3) 51 | ||
|
| not program if LINKS not used) |
|
|
| |
|
|
|
|
|
| |
[350] | TLM Restore | Telephone line trouble restore | MA/R | (3) 51 | ||
|
|
|
|
|
| |
Gen System Trouble/Rest. | “Service Required” trouble occurs (view troubles using | MA/R | (3) 33 | |||
|
| [*][2])/trouble restored |
|
|
| |
|
|
|
|
|
| |
Gen System Supervisory | control panel loses/restores communications with mod- | MA/R | (3) 33 | |||
| Trouble/Rest. | ule(s) connected to the Keybus |
|
|
| |
|
|
|
|
|
| |
[351] | Line 1 or 2 FTC Restoral | control panel has restored communications to central | MA/R | (3) 54 | ||
|
| station on line 1 or 2 (after FTC) |
|
|
| |
|
|
|
|
|
| |
[351] | Event Buffer is 75% Full | event buffer is almost full since last upload | MA/R | (6) 23 | ||
[351] | DLS Lead In | downloading session start | MA/R | (4) 11 | ||
|
|
|
|
|
| |
[351] | DLS Lead Out | downloading session complete | MA/R | (4) 12 | ||
|
|
|
|
|
| |
[351] | Zone Fault/Rest. | one or more zones have faults/restored | MA/R | (3) 72 | ||
[351] | Delinquency | programmed amount of time (days or hours) for delin- | MA/R | (4) 54*** | ||
|
| quency has expired without zone activity or without sys- |
|
|
| |
|
| tem being armed |
|
|
| |
|
|
|
|
|
| |
[352] | Periodic Test | periodic system test transmission | T | (6) A2 | ||
|
|
|
|
|
| |
[352] | System Test | [*][6] bell/communications test | T | (6) A1 | ||
[352] | LINKS Test | LINKS test transmission | T | (6) A3 | ||
|
|
|
|
|
| |
[353] | Wireless Device Low Bat- | wireless zones (WLS904, WLS905, WLS907); panic | MA/R | (3) 84 | ||
| tery Trouble/Rest. | pendants (WLS908); handheld keypads (WLS910); |
|
|
| |
|
| wireless keys (WLS909) have low battery/all low batter- |
|
|
| |
|
| ies restored |
|
|
| |
|
|
|
|
|
|
*A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
**UU = user number
***Program the “Fail to close” event code [(4)54] to report either closing or activity delinquency. Make sure your central station is aware of the application of this reporting code.
Table2: Contact ID Zone Alarm/Restoral Event Codes (as per ADEMCO):
Program any of these codes for zone alarms/restorals when using the standard
Medical Alarms | (1)34 | Entry / Exit | |
(1)AA | Medical | (1)35 | Day / Night |
(1)A1 | Pendant Transmitter | (1)36 | Outdoor |
(1)A2 | Fail to Report In | (1)37 | Tamper |
Fire Alarms | (1)38 | Near Alarm | |
(1)1A | Fire Alarm | General Alarms | |
(1)11 Smoke | (1)4A | General Alarm | |
(1)12 | Combustion | (1)43 | Exp. module failure |
(1)13 | Water Flow | (1)44 | Sensor tamper |
(1)14 Heat | (1)45 Module Tamper | ||
(1)15 | Pull Station | (1)4A Cross Zone Police Code | |
(1)16 | Duct | 24 Hour | |
(1)17 Flame | (1)5A | 24 Hour | |
(1)18 Near Alarm | (1)51 Gas detected | ||
Panic Alarms | (1)52 | Refrigeration | |
(1)2A | Panic | (1)53 | Loss of Heat |
(1)21 Duress | (1)54 Water Leakage | ||
(1)22 | Silent | (1)55 | Foil Break |
(1)23 | Audible | (1)56 | Day Trouble |
Burglar Alarms | (1)57 | Low bottled Gas level | |
(1)3A | Burglary | (1)58 | High Temp |
(1)31 | Perimeter | (1)59 | Low Temp |
(1)32 | Interior | (1)61 | Loss of Air Flow |
(1)33 24 Hour
Table 3: SIA Format Automatic Zone Alarm/Restoral Codes
|
| SIA Auto Rep |
Zone Definition |
| Codes* |
|
|
|
|
| Zone Alm/Rest. |
|
|
|
Delay, Instant, Interior, Delay |
| |
Stay/Away, Interior Stay/Away, |
|
|
24Hr Burg. |
|
|
|
|
|
Standard 24Hr Fire, Delayed |
| |
24Hr Fire |
|
|
|
|
|
24Hr Supervisory |
| |
|
|
|
24Hr Supervisory Buzzer |
| |
|
|
|
24Hr Sprinkler |
| |
|
|
|
24Hr Gas |
| |
|
|
|
24Hr Heat |
| |
|
|
|
24Hr Medical |
| |
|
|
|
24Hr Emergency |
| |
|
|
|
24Hr Waterflow |
| |
|
|
|
24Hr Freeze |
| |
|
|
|
24Hr Holdup |
| |
|
|
|
24Hr Panic |
| |
|
|
|
Latching 24Hr |
| |
|
|
|
| * | ZZ = zones |
|
|
|
WWW.DIYALARMFORUM.COM