Section 3: Keypad Commands
Use any system keypad to enter commands and/or program the PC1555MX security system. The LED keypad uses func- tion and zone indicator lights to represent alarm functions and status. The LCD keypad provides a written description on the liquid crystal display and uses function indicator lights to communicate alarm status to the user.
The PC1555MX Instruction Manual provides basic directions for arming and disarming the system, bypassing zones and performing user functions from the keypads. The following sections provide additional details on these functions.
3.1Arming and Disarming
For a description of basic arming and disarming, please see the PC1555MX Instruction Manual. For other methods of arm- ing, please refer to “[*][0] Quick Arm”, “[*][9] Arming Without Entry Delay” and 3.5 “Function Keys” on page 11.
NOTE: The event buffer will log “Armed in Stay Mode” or “Armed in Away Mode” whenever the system is armed.
In an attempt to prevent false alarms, the Audible Exit Fault will notify the user of an improper exit when they arm their sys- tem. If a non
3.2Auto Bypass – Stay Arming
Stay arming allows the user to arm the system without leaving the premises. All zones programmed as stay/away will be bypassed when the user stay arms the system, so that the user does not have to bypass interior zones manually. (See
5.2“Zone Programming” on page 15.)
When the system is armed using a valid access code, if any zones on the system have been programmed as stay/away zones, the Bypass light will turn ON. The panel will then moni- tor all zones programmed as Delay 1 and Delay 2 zones, such as designated entry/exit doors. If a delay zone is not violated by the end of the exit delay, the panel will bypass all stay/away zones. The Bypass light will remain on to inform the user that the interior zones have been automatically bypassed by the panel. If a delay zone is violated during the exit delay, the sys- tem will arm in Away mode and all stay/away zones will be active after the exit delay expires.
The user can arm the stay/away zones at any time by entering the [*][1] keypad command. (See “[*][1] Bypassing and Acti- vating Stay/Away Zones” on page 8.)
Stay arming can also be initiated by pressing and holding the Stay function key for two seconds on the PC5508Z and LCD5500Z keypads, if programmed by the installer. For more information regarding Stay arming, please see 3.5 “Function Keys” on page 11.
3.3Automatic Arming
The system can be programmed to
rect Time of Day. For programming the clock and
When the system’s internal clock matches the
NOTE: If
If no code is entered, the panel will
–if programmed – to indicate to the central station that the system is not secure. If the zone is restored, the panel will add the zone back into the system.
NOTE: Auto arming can only be cancelled by entering a valid access code at any keypad.
3.4[*] Commands
The [*] key commands provide an easy way for the user to access basic system programming – such as programming access codes or bypassing zones. The user can also use the
[*]key commands to check on the system’s status, including viewing trouble conditions and displaying the event buffer on the LCD keypad.
The [*] key commands can be performed from both LCD and LED keypads. The LED keypad uses the zone indicator lights to display command information. The LCD display provides written information, guiding the user through each command. The commands in this section are explained as viewed from an LED keypad. When using an LCD keypad, use the arrow keys (< >) to scroll through information provided. Otherwise, the functions remain the same for both keypad types.
[*][1] Bypassing and Activating Stay/Away Zones Use the [*][1] keypad command to bypass individual zones. A bypassed zone will not cause an alarm.
NOTE: Zones can only be bypassed when the system is not armed.
If the Code Required for Bypass option is enabled (section [015], option [5]), only access codes with the bypass attribute enabled will be able to bypass zones. (See 5.1 “Programming Security Codes” on page 15.)
If the Bypass Status Displayed While Armed option is cho- sen, the Bypass light will be ON while the system is armed to indicate any bypassed zones. (See 5.17 “Arming/Disarming Options” on page 23.)
NOTE: When you disarm the system, all
Activate Stay/Away Zones
If the system is armed in stay mode, the [*][1] command can be used to activate the stay/away zones.
WWW.DIYALARMFORUM.COM