P r o g r a m m i n g W o r k s h e e t s
Keypad Programming
[000]Keypad Enrollment (Section 2.6 “Keypad Assignment” on page 5)
NOTE: This must be done at each keypad requiring programming.
[0]Slot [Valid entries are
[1]Function Key 1 Assignment (Valid entries are
[2]Function Key 2 Assignment (Valid entries are
[3]Function Key 3 Assignment (Valid entries are
[4]Function Key 4 Assignment (Valid entries are
[5]Function Key 5 Assignment (Valid entries are
Function Key Options:
00 | Null Key | 08 | [*][1] Bypass Mode | 16 | [*][0] Quick Exit |
01 | For future use | 09 | [*][2] Trouble Display | 17 | [*][1] Reactivate Stay/Away’s |
02 | For future use | 10 | [*][3] Alarm Memory | 18 | Identified Voice Prompted Help |
03 | Stay Arm | 11 | [*][5] User Programming | 19 | Command Output 3 |
04 | Away Arm | 12 | [*][6] User Functions | 20 | For Future Use |
05 | [*][9] | 13 | Command Output #1 [*][7][1] | 21 | Command Output 4 |
06 | [*][4] Chime On / Off | 14 | Command Output #2 [*][7][2] |
|
|
07 | 15 | General Voice Prompted Help |
|
|
|
| Slot |
| Function | Function | Function | Function | Function | |||||
|
|
|
| Key 1 | Key 2 | Key 3 | Key 4 | Key 5 | |||||
LED Defaults |
| 11 |
|
| 03 |
| 04 |
| 06 |
| 14 |
| 16 |
LCD Defaults |
| 18 |
|
| 03 |
| 04 |
| 06 |
| 14 |
| 16 |
KEYPAD 1 | I | I | I | I | I | I | I | I | I | I | I | I | I |
KEYPAD 2 | I | I | I | I | I | I | I | I | I | I | I | I | I |
KEYPAD 3 | I | I | I | I | I | I | I | I | I | I | I | I | I |
KEYPAD 4 | I | I | I | I | I | I | I | I | I | I | I | I | I |
KEYPAD 5 | I | I | I | I | I | I | I | I | I | I | I | I | I |
KEYPAD 6 | I | I | I | I | I | I | I | I | I | I | I | I | I |
KEYPAD 7 | I | I | I | I | I | I | I | I | I | I | I | I | I |
KEYPAD 8 | I | I | I | I | I | I | I | I | I | I | I | I | I |
Basic Programming
Zone Definitions |
|
|
|
|
| |
00 | Null Zone (Not Used) | 10 | 24 | Hour Supervisory Buzzer | 20 | 24 Hour Freeze |
01 | Delay 1 | 11 | 24 | Hour Burglary | 21 | 24 Hour Latching Tamper |
02 | Delay 2 | 12 | 24 | Hour Holdup | 22 | Momentary Keyswitch Arm |
03 | Instant | 13 | 24 | Hour Gas | 23 | Maintained Keyswitch Arm |
04 | Interior | 14 | 24 | Hour Heating (N/C zone) | 24 | LINKS Answer |
05 | Interior, Stay/Away | 15 | 24 | Hour Medical | 25 | Interior Delay |
06 | Delay, Stay/Away | 16 | 24 | Hour Panic | 87 | Delay 24 Hour Fire (Wireless) |
07 | Delayed 24 Hour Fire (Hardwired) | 17 | 24 | Hour Emergency | 88 | Standard 24 Hour Fire (Wireless) |
08 | Standard 24 Hour Fire (Hardwired) | 18 | 24 | Hour Sprinkler |
|
|
09 | 24 Hour Supervisory | 19 | 24 | Hour Water |
|
|
NOTE: Keypads must be installed to use
NOTE: Keypad zones are assigned in section [020]. Zone Attributes are assigned in sections [101] - [132]. Zone assignment is in sections [202] - [205].
[001]Zone
Default |
| Default |
|
01 | I I I Zone 1 | 04 | I I I Zone 5 |
03
03
03
I I I
I I I
I I I
Zone 2 | 04 |
Zone 3 | 00 |
Zone 4 | 00 |
I I I
I I I
I I I
Zone 6
Zone 7
Zone 8
WWW.DIYALARMFORUM.COM
29