Cornelius 250 manual Beverage not Sweet Enough, Beverages not Cold Units with BUILT-IN, Cold Plate

Page 9

Trouble

 

Probable Cause

BEVERAGE NOT SWEET ENOUGH.

A.

Empty syrup tank.

 

B.

Faucet brix requires adjusting.

 

 

 

BEVERAGES NOT COLD (UNITS WITH BUILT–IN

A.

Unit standing with no ice in hopper – no ice in

COLD PLATE).

 

cold plate cabinet.

 

 

 

FLAVOR SYRUPS DO NOT DISPENSE

A.

No 24 volt power to PC board.

 

B.

No CO2 pressure.

 

C.

Empty syrup tank.

 

D.

Kinked tubing.

 

E.

Clogged inner nozzle.

 

F.

Defective PC board.

 

G.

Defective harness from keypad.

 

H.

Defective Flow control.

 

I.

Defective solenoid harness.

 

J.

Defective keypad.

 

 

 

FLAVOR DISPENSES FOR MORE THAN 1 SEC

A.

Dip switch settings on control board incorrect.

 

B.

PC board defective.

 

C.

Defective flow control.

 

 

 

FLAVOR DISPENSES MORE THAN .5 OZ

A.

Dip switch settings on control board incorrect.

 

B.

Flow control incorrectly set.

 

C.

PC board defective.

 

D.

Defective flow control.

NOTE: Contact your local syrup or beverage equipment distributor for additional information and troubleshooting of beverage system.

7

92108OPR

Image 9
Contents This Document Contains Important Information ICE/BEVERAGE DispenserTable of Contents Maintenance Cleaning InstructionsSTART-UP & Operating Instructions Important Perform the following at least once a month DispenserBeverage System CleaningSanitize syrup lines, B-I-B Systems Sanitize Flavor syrup lines, B-I-B System Troubleshooting Beverages not Cold Units with BUILT-IN Beverage not Sweet EnoughCold Plate Flavor Syrups do not DispenseWarranty IMI Cornelius INC