Foster KS 60 user manual Installation room

Page 7

Installation room

For proper operation of the gas appliance, it is essential that the room has a natural air flow from openings on the external walls providing sufficient air for combustion of the gas. These openings must have a free air -flow cross-section of at least 100 cm² (it is possible to make one or more openings).

The exhaust of the combustion residual products must occur through hoods connected to chimney flues or directly to the outdoors. If it is not possible to install a hood, an electric fan must be applied to the external wall or window of the room provided that the room has the required air inlet openings according to current standards. This electric fan must have a capacity that guarantees, for a kitchen, an hourly air renewal of 3-5 times its volume.

26

Image 7 Contents
KS 60 gas, cod Page Page +*$ %#1 YELLOW-GREEN = Earth Blue = Neutral Brown = Phase InstallationInstallation room ##$% 85-/# Connection to the GAS Supply Do not USE Open Flames When Searching for GAS LeaksAdaptation to the gas in use Setting of the minimum Before Using the Oven Precautions and General Suggestions During Operation Turning on the OvenUsing the Spit Page Instructions for Installing Knob Guard Panettone or focaccia Real focaccia ‘Sublime’ cake Pie crust Cleaning and Maintenance of the Oven How to remove the oven door Cleaning the side racks