Foster KS 60 Connection to the GAS Supply, Do not USE Open Flames When Searching for GAS Leaks

Page 9

CONNECTION TO THE GAS SUPPLY

The supply system must be compliant with the current local standards in the country of use. The type of gas for which the oven has been regulated is indicated on the serial number plate located on one of the side edges of the cavity (visible with the door open) and on the packaging. Before carrying out the connection, the oven must be adapted to the type of gas that will be used. The connection between the gas fitting, ramp and pipe can be carried out in one of the following ways (see the following drawing):

1.Using an attachment without seals (the oven attachment is conical: (the oven attachment is conical: ISO R 7).

2.Using the seal provided.

Attention: when finished, check that there are no gas leaks.

Use soap and water or special liquids to make sure that there are no gas leaks.

DO NOT USE OPEN FLAMES WHEN SEARCHING FOR GAS LEAKS.

Warning: the use of a rubber flexible hose fastened with hose clamps is prohibited because it cannot be inspected.

RAMP

SEAL

2)

FLEXIBLE HOSE

1)

28

Image 9 Contents
KS 60 gas, cod Page Page +*$ %#1 YELLOW-GREEN = Earth Blue = Neutral Brown = Phase InstallationInstallation room ##$% 85-/# Connection to the GAS Supply Do not USE Open Flames When Searching for GAS LeaksAdaptation to the gas in use Setting of the minimum Before Using the Oven Precautions and General Suggestions During Operation Turning on the OvenUsing the Spit Page Instructions for Installing Knob Guard Panettone or focaccia Real focaccia ‘Sublime’ cake Pie crust Cleaning and Maintenance of the Oven How to remove the oven door Cleaning the side racks