Foster 7331 230, e 7370 230 user manual Electrical Connection, Connection of the hob

Page 15

ELECTRICAL CONNECTION

The installation of this appliance and the connection to the electrical network should be entrusted only to an electrician perfectly to the fact of the normative regulations and which respects them scrupulously.

Protection against the parts under tension must be ensured after the building-in.

The data of connection necessary are on the stickers place on the hob casing near the connection box.

The connection to the main must be made using an earthed plug or via an omnipolar circuit breaking device with a contact opening of at least 3 mm.

The electrical circuit must be separated from the network by adapted devices, for example: circuit breakers, fuses or contactors.

Caution!

This appliance has only to be connected to a network 230 V~ 50/60 Hz.

Connect always the earth wire.

Respect the connection diagram.

The connection box is located underneath at the back of the hob casing. To open the cover use a medium screwdriver. Place it in the slits and open the cover.

Mains

Connection

Cable diameter

Cable

Protection calibre

230V~ 50/60Hz

1 Phase + N

3 x 2,5 mm²

H 05 VV - F

25 A *

H 05 RR - F

 

 

 

 

400V~ 50/60Hz

2 Phases + N

4 x 1.5 mm²

H 05 VV - F

16 A *

H 05 RR - F

 

 

 

 

* calculated with the simultaneous factor following the standard EN 60 335-2-6/1990

Connection of the hob

Setting up the configurations:

For the various kinds of connection, use the brass bridges which are in the box next the terminal

Monophase 230V~1P+N

Put the 1st bridge between terminal 1 and 2, the 2nd between 3 and 4.

Attach the earth to the terminate “earth”, the neutral N to terminal 4 or 3, the Phase L to one of the terminals 1 or 2.

Biphase 400V~2P+N

Put a bridge between terminal 3 and 4.

Attach the earth to the terminate “earth”, the neutral N to terminal 4 or 3, the Phase L1 to the terminals 1 and the Phase L2 to the terminal 2.

Caution! Be careful that the cables are correctly engaged and tightened.

We cannot be held responsible for any incident resulting from incorrect connection or which could arise from the use of an appliance which has not been earthed or has been equipped with a faulty earth connection.

29

Image 15
Contents Cod 230 e 7370 Dear clients SummarySafety Precautions before usingUsing the appliance Precautions not to damage the appliance Precautions in case of appliance failureOther protections Technical characteristics Description of the ApplianceControl panel STARTING-UP and Appliance Management USE of the ApplianceResidual heat indication ∙ Start-up/ switch off the hob Action Control panel DisplayStarting-up Pan detectionAction Control panel Display Timer∙ Power management Booster function∙ Automatic stop at the end of the cooking time ∙ Egg timer function Action Control panelAutomatic cooking ∙ To stop the cooking time Action Control panel DisplayPan quality Cooking AdvicesPan dimension Control panel lockingMaintenance and Cleaning Examples of cooking power settingSwitch-off the appliance before cleaning Control panel displays U What to do in Case of a Problem Symbol E 4 displays Hob or the cooking zone doesn’t start-upEnvironment Preservation Installation Instructions How to stick the gasketFitting installing ∙ The cut out sizes are Connection of the hob Electrical ConnectionFoster spa