(7 7/8") 200
(13 5/8") 346
Fig. 19
Fig. 20 |
Note:
the extractor hood is to be installed to a kitchen ceiling or suspended ceiling. Ensure that the ceiling is capable of providing a firm hold for a maximum weight of hood and accessories of 60 kg.
Before marking the securing holes, make sure that no electricity wires or water pipes or other wires/ pipes are laid at the drilling points in the ceiling.
Before installation check the enclosed wall plugs and screws are suitable for your ceiling. If neces- sary use special wall plugs.
Installation:
1.Using the drilling template mark the position of the screws on the ceiling.
2.Drill 4 holes Ø 8 mm for the wall plugs. Push the plugs flush with the ceiling (Fig. 19).
3.Turn two screws to a 10 mm gap. Both screws are placed in a position, in which at a later stage of the installation the
4.Place the hood on a suitable base. Connect the air outlet pipe to the hood.
5.Screw the support frame to the hood with
4 screws. The marking “FRONT” must be on the same side as the control panel (Fig. 20).
Ventilation ducts LK
17