Glen Dimplex Home Appliances Ltd BI 90 G manual Installation Instructions

Page 26

Installation Instructions

Before you start: Please read the instructions. Planning your installation will save you time and effort.

Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure) and the adjustment of the appliance are compatible. The adjustment conditions are stated on the data badge.

Thisapplianceis not connected to a combustion evacuation device. It shall be installed and connected in accordance with current installation regulation. Particular attention shall be given to the relevant requirements regarding ventilation.

In your own interest and that of safety, it is the law that all gas appliances be installed and serviced by competent persons. GAS SAFE registered installers undertake to work to satisfactory standards.

Where regulations or standards have been revised since this handbook was printed, always use the latest edition.

In the UK the regulations and standards are as follows:

1.Gas Safety Regulations (Installation and Use).

2.Building Regulations - Issued by the Department of the Environment.

3.Building Standards (Scotland ) (Consolidated) - Issued by the Scottish Development Department.

4.The current I.E.E. Wiring Regulations.

5.Electricity at Work Regulations.

6.BS 6172 Installation of Domestic Gas cooking Appliances

7.Installation & Servicing Instructions for this appliance.

For installation in countries other than the UK, the appliance must be connected in

accordance with all local gas and electrical regulations. In the Republic of Ireland, Installers should refer to IS813 Domestic Gas Appliances.

Ventilation Requirements

The room containing the appliance should have an air supply in accordance with BS 5440: Part 2.

All rooms require an openable window, or equivalent, and some rooms will require a permanent vent as well.

For room volumes up to 5m3 an air vent of 100cm2 is required.

If the room has a door that opens directly to the outside, or the room exceeds 10m3, NO AIR VENT is required.

For room volumes between 5m3 and 10m3 an air vent of 50cm2 is required.

If there are other fuel burning appliances in the same room, BS 5440: Part 2 should be consulted to determine the air vent requirements.

This appliance must not be installed in a bed sitting room of less than 20m3 or in a bathroom or shower room.

Windows and permanent vents should therefore not be blocked or removed without first consulting a GAS SAFE gas installer.

In the Republic of Ireland, refer to relevant Irish Standards for correct ventilation requirements.

Failure to install appliances correctly is dangerous and could lead to prosecution.This appliance is not connected to a combust ion products evacuation device. It shall be installed and connected in accordance with current installation regulations. Particular attention shall be given to the relevant requirements regarding ventilation.

24

Image 26
Contents Belling BI 90 G If you smell gas Important NoticeContents Introduction Your 1st Year GuaranteeEvent of a power cut Ventilation For your safetyCooling fan To replace a light bulb To replace an oven light bulb Glass door panelsCondensation Environmental ProtectionBe Safe Not Sorry Never use the appliance for heating a roomPreheating Using the GrillGrill operation Aluminium foilUsing the grill Oven shelves Using the OvensOven furniture Baking tray and roasting tins Ignition top oven Using the top ovenReplacing light bulbs Zones of heat top ovenTop oven baking guide CakesBaking guide hints Pre-heatingZones of heat main oven Main oven baking guide Roasting guide LambRoast turkey Traditional fruit cakesCooking frozen & chilled foods Slow cookingUsing the Oven Semi-Automatic cooking in the mainovenProgrammer / Clock Programmer buttons To select an alarm toneSetting the minute minder To set the time of daySemi-automatic cooking Semi-automatic cooking Duration method End Time methodChrome plated parts CleaningAlways let the appliance cool before cleaning Enamel surfacesGlass parts Painted, plastic and metal finish parts if fittedStainless steel surfaces stainless steel finish models only Installation Instructions UK the regulations and standards are as followsInstallation Instructions Siting the applianceDimensions Typical example of a double pole fuse spur outlet Connect to the electricity supplyUse a 13 amp fuse Connect to gas supply Make sure all connections are gas soundSecure appliance into housing unit Tosecure appliancetohousingunitCommissioning Pressure test point Pressure settingBefore leaving the installation Burner aerationTechnical Data Page Page Belling Customer Care 0844 815