Turning Off the Power Supply

Before attempting to connect the appliance to power, turn off the electrical power supply. Also, always turn off electrical power to the appliance prior to servicing it.

WARNING

WARNING – Failure to disconnect power may result in electrical shock or fire hazard.

Electrical Connection

WARNING

1.This appliance must be connected to a grounded, metallic, permanent wiring system. Alternatively, a grounding conductor should be connected to the grounding terminal or lead on the appliance. Failure to do so may result in an electrical shock hazard.

2.Do not install a fuse in the neutral or ground circuit. A fuse in the neutral or ground circuit may result in an electrical shock hazard.

Grounding Instructions

The appliance must be connected to the power supply with copper wire only. The use of aluminum wire may result in unsatisfactory connections. Flexible armored or non-metallic, sheathed copper cable (with grounding wire) should be used to connect the appliance to the junction box. A UL-listed connector must be used to directly connect the cable to the junction box.

Be certain to locate the junction box such that the electrical supply may be easily disconnected in the event that service becomes necessary. Also, provide extra slack in the cable to allow the oven to slide forward for servicing.

This appliance must be electrically grounded.

With the oven positioned directly in front of the cabinet cutout, feed the appliance conduit to the electrical junction box. Then, depending upon local codes, utilize one of the following techniques to connect the appliance to the electrical power supply:

A. Connecting to a Four-Wire Electrical System

1.Separate the green and white appliance wires.

2.Connect the white appliance wire to the neutral (white) supply wire in the junction box.

3.Connect the black appliance wire to the black (L1) power supply wire in the junction box.

4.Connect the red appliance wire to the red (L2) power supply wire in the junction box.

5.Connect the green appliance wire to the green house grounding wire

Instructions

Cable from

power supply

 

Junction

 

box

RED

WHITE

RED

WHITE

 

GREEN

BLACK

GREEN

BLACK

 

 

Wire nut

 

(4 places)

Conduit from

 

appliance

Connecting the Appliance to a Four-Wire Power Supply

WARNING

WARNING – Do not connect the green appliance wire to the neutral (white) junction box wire unless local building codes permit.

Cable from

power supply

 

Junction

 

box

RED

GREEN

 

RED

WHITE

 

WHITE

 

BLACK

 

BLACK

 

Wire nut

 

(3 places)

 

Conduit from

 

appliance

Connecting the Appliance Ground to Supply Neutral

B.Connecting the Green Appliance Wire to the Neutral (White) Supply Wire – Where Local Codes Permit

1.Connect the green and white appliance wires to the neutral (white) supply wire in the junction box.

2.Connect the black appliance wire to the black (L1) power supply wire in the junction box.

3.Connect the red appliance wire to the black (L2) power supply wire in the junction box.

7

Image 9
Contents Installation Instructions Classic Wall Ovens Page Table of Contents Appliance SafetyInstallation Recommendations Important Safety Instructions Product Dimensions Design SpecificationsOverall Dimensions Verifying the Package Contents Installation SpecificationsInstallation Planning Installing the Support Platform in the cabinetRemoving the Oven Doors Installation InstructionsTurning Off the Power Supply InstallationInstructions Electrical ConnectionMounting the Oven Installing the Exhaust Grill Reinstalling the Oven DoorsVerifying Oven Operation Service Information Page Page Page Phone 800