Cres Cor CO151FW1818B, CO151XW185B HOW to Adjust the Door Latch, HOT Unit Removal, HWUA6 XWUA5

Page 8

Ovens

FL-2270

Rev. 10 (4/08)

Page 8 of 13

5925 Heisley Road • Mentor, OH 44060-1833

MAINTENANCE INSTRUCTIONS

TROUBLE-SHOOTING GUIDE, continued

HOW TO ADJUST THE DOOR LATCH:

1.For vertical (up and down movement) adjustment:

a.Loosen (2) screws located in magnetic strike.

b.Move strike up or down for alignment to magnet on latch.

c.Tighten screws to secure

2.For horizontal (greater or lesser magnetic draw) adjustment:

a.Loosen (4) screws in door latch.

b.Move latch forward or backward to adjust magnetism.

c.Tighten screws to secure.

HOT UNIT REMOVAL:

1.

Disconnect power cord from wall outlet.

 

2.

For half-size model: CO151HW Series, remove

 

 

screws around top cover.

 

3.

Disconnect the yellow cord between top and bottom,

 

 

in the back of the cabinet (see Figure 2).

 

4.

Lift off Hot Unit.

FIGURE 2

HOT UNIT REMOVAL

REPLACEMENT PARTS: Include all information on nameplate when ordering parts.

Cabinet Replacement Parts

MODEL PREFIX CO-151, RO-151

DESCRIPTION

-FPWUA (12), (18)

-FWUA (12), (18)

-FW1332

-HWUA6

-XWUA5

Hot Unit, 208V, 1 Ph

HU675013

HU675025

HU675029

HU675037

HU675037

Hot Unit, 208V, 3 Ph

HU675015

HU675027

HU675031

HU675039

HU675039

Hot Unit, 240V, 1 Ph

HU675014

HU675026

HU675030

HU675038

HU675038

Hot Unit, 240V, 3 Ph

HU675016

HU675028

HU675032

HU675040

HU675040

Door Latch Kit

1006-120-01-K

1006-120-01-K

1006-120-01-K

1006-120-01-K

1006-120-01-K

Door Strike

1006-120-02-K

1006-120-02-K

1006-120-02-K

1006-120-02-K

1006-120-02-K

Door Hinge

0519-074-K

0519-074-K

0519-074-K

0519-074-K

0519-074-K

Door Assembly

1221-525-K

1221-525-K

1221-543-K

1221-525-K

1221-545-K

Door Gasket

0861-185-K

0861-185-K

0861-184

0861-185-K

0861-250-K

Angles or Racks

0621-281-SS-K

0621-281-SS-K

1104-108

0621-281-SS-K

0621-281-SS-K

Side Handles (2),

0911-102

0911-102

0911-102

0911-102

0911-102

Black Recessed

 

 

 

 

 

Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

Image 8
Contents INSTALLATION, Operation and Maintenance Manual for Cres Cor Aquatemp HumidityConvection and Retherm Ovens CO151FUA12B CO151HUA6B CO151FWUA12B CO151HWUA6BTable of Contents Installation Instructions Venting Your OvenNema Retherm OvensOperating Instructions Cook Humidity Operation HOW to Cook HOW to ProofOperating Instructions Standard OperationSoil Cleaner Method Maintenance Water PANMaintenance Cabinet Maintenance Instructions Problem Possible Cause SolutionHOW to Adjust the Door Latch HOT Unit RemovalHOT Unit Removal Model Prefix CO-151, RO-151 DescriptionItem Description Replacement PartsHot Unit Replacement Parts For Ovens CO or RO 151FW Series For PASS-THRU Ovens CO or RO 151FW Series Wiring Diagram Single Phase PhaseWiring Diagram Three Phase Phase