York F*FV, F*FP specifications Coil Technical Data, Cooling Capacity

Page 3

295421-YTG-B-0707

COIL TECHNICAL DATA

 

 

Refrigerant

Face

Deep

Fins

 

Coil

Tube

Tube

 

Metering

Models

Application

Connection

Area

Per

Slab Size

Fin. Type

 

 

Type

(Sq. Ft.)

Rows

Inch

 

 

 

Geometry

Dia.

 

Device

 

 

H

 

W

 

F4FP024H06T2A

A/C & HP

 

3.40

2

14

14

 

17.5

 

 

 

TXV-2A

 

 

 

 

 

 

 

 

 

 

 

 

 

F4FP024H06T2B

A/C & HP

 

3.40

2

14

14

 

17.5

 

 

 

TXV-2B

 

 

 

 

 

 

 

 

 

 

 

 

 

F4FP030H06T2A

A/C & HP

 

3.89

2

14

16

 

17.5

 

 

 

TXV-2A

 

 

 

 

 

 

 

 

 

 

 

 

 

F4FP036H06T2A

A/C & HP

 

3.40

3

12

14

 

17.5

 

 

 

TXV-2A

 

 

 

 

 

 

 

 

 

 

 

 

 

F4FP040H06T2A

A/C & HP

 

3.89

3

11

16

 

17.5

 

 

 

TXV-2A

 

 

 

 

 

 

 

 

 

 

 

 

 

F4FP040H06T2C

A/C & HP

Sweat

3.89

3

11

16

 

17.5

1 x .886

3/8

Enhanced

TXV-2C

 

 

 

 

 

 

 

 

 

F4FP042H06T2A

A/C & HP

3.89

3

11

16

 

17.5

TXV-2A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F4FP042H06T2C

A/C & HP

 

3.89

3

11

16

 

17.5

 

 

 

TXV-2C

 

 

 

 

 

 

 

 

 

 

 

 

 

F4FP045H06T2C

A/C & HP

 

5.83

3

12

24

 

17.5

 

 

 

TXV-2C

 

 

 

 

 

 

 

 

 

 

 

 

 

F5FP048H06T2C

A/C & HP

 

5.35

3

12

22

 

17.5

 

 

 

TXV-2C

 

 

 

 

 

 

 

 

 

 

 

 

 

F5FP060H06T2C

A/C & HP

 

5.83

3

12

24

 

17.5

 

 

 

TXV-2C

 

 

 

 

 

 

 

 

 

 

 

 

 

F4FV060H06T2C

A/C & HP

 

5.83

3

12

24

 

17.5

 

 

 

TXV-2C

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING CAPACITY

Blower

Rated

Entering

MBH @ Evaporator Temperature and Corresponding Pressure °F /

Air °F

 

 

 

PSIG

 

Model

CFM

 

 

 

 

(Dry / Wet Bulb)

35 / 61.5

 

40 / 68.5

 

45 / 76.0

50 / 84.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Upflow / Horizontal Positions Only

 

 

 

 

 

 

85 / 72

36.3

 

33.0

 

29.5

25.6

F4FP024H06T2*

830

80 / 67

33.4

 

30.2

 

26.7

23.1

75 / 62

27.4

 

24.3

 

21.0

17.7

 

 

 

 

 

 

70 / 57

22.2

 

19.3

 

16.2

12.6

 

 

 

 

 

 

 

 

 

 

 

85 / 72

41.5

 

37.8

 

33.7

29.5

F4FP030H06T2*

1050

80 / 67

36.2

 

32.4

 

28.6

24.5

75 / 62

29.1

 

25.3

 

24.0

19.2

 

 

 

 

 

 

70 / 57

24.1

 

21.5

 

18.7

15.8

 

 

 

 

 

 

 

 

 

 

 

85 / 72

53.4

 

48.6

 

43.4

38.3

F4FP036H06T2*

1250

80 / 67

42.8

 

37.8

 

33.1

28.2

75 / 62

33.4

 

28.1

 

30.6

22.8

 

 

 

 

 

 

70 / 57

28.7

 

26.5

 

24.5

22.8

 

 

 

 

 

 

 

 

 

 

 

85 / 72

55.3

 

47.5

 

39.6

31.2

F4FP040H06T2*

1050

80 / 67

44.2

 

37.1

 

30.2

23.1

75 / 62

34.5

 

27.5

 

22.4

18.7

 

 

 

 

 

 

70 / 57

29.6

 

26.0

 

22.4

18.7

 

 

 

 

 

 

 

 

 

 

 

85 / 72

88.4

 

76.0

 

63.3

50.0

F4FP042H06T2*

1400

80 / 67

70.8

 

59.4

 

48.4

37.0

75 / 62

55.2

 

43.9

 

35.8

29.9

 

 

 

 

 

 

70 / 57

47.4

 

41.5

 

35.8

29.9

 

 

 

 

 

 

 

 

 

 

 

85 / 72

92.7

 

78.1

 

63.4

48.1

F4FP045H06T2*

1400

80 / 67

74.2

 

61.3

 

48.4

35.4

75 / 62

57.8

 

45.3

 

35.7

28.6

 

 

 

 

 

 

70 / 57

49.7

 

42.8

 

35.7

28.6

 

 

 

 

 

 

 

 

 

 

 

85 / 72

100.5

 

86.4

 

72.0

56.8

F5FP048H06T2*

1600

80 / 67

80.4

 

67.5

 

55.0

42.1

75 / 62

62.7

 

49.9

 

40.7

34.0

 

 

 

 

 

 

70 / 57

53.9

 

47.2

 

40.7

34.0

 

 

 

 

 

 

 

 

 

 

 

85 / 72

119.9

 

101.0

 

82.0

62.2

F5FP060H06T2*

1850

80 / 67

96.0

 

79.2

 

62.6

45.8

75 / 62

74.8

 

58.6

 

46.2

37.0

 

 

 

 

 

 

70 / 57

64.3

 

55.4

 

46.2

37.0

 

 

 

 

 

 

 

 

 

 

 

85 / 72

122.0

 

103.1

 

84.1

64.3

F4FV060H06T2*

1980

80 / 67

98.1

 

81.3

 

64.7

47.9

75 / 62

76.9

 

60.7

 

50.3

39.1

 

 

 

 

 

 

70 / 57

66.4

 

57.5

 

48.3

39.1

 

 

 

 

 

 

 

 

 

Unitary Products Group

3

Image 3
Contents Description FeaturesLiquid DimensionsDimensions PowerCooling Capacity Coil Technical DataAccessories LimitationsExtended Airflow DATA1 for 230 Volt Heat Pump Models Rated Airflow Extended AIR Flow DATA1 for 208 Volt Heat Pump ModelsApplication FACTORS-RELATED CFM VS. Actual CFM Blower Motor VoltElectric Heat CFM Delay ProfileVoltage Shipping/Operating Weight lbsBlower Diameter Width Motor Nominal RPMKW & MBH Conversions for Total Power Input Requirement Total Heat2W1 Only W2 Only W1 + W2 125 2HK16502506B 104.2 123.1 139.0 Electrical Data 1∅ Single Source Power Supply Copper WireHeater Field Wiring Model1Electrical Data 1 Ø MULTI-SOURCE Power Supply Copper Wire Heater ModelTotal Heat1 Electrical Data 3∅ Single Source Powersupply Copper Wire 75C Wire Size AWGHeater Models Min. Circuit Ampacity Series Field Wiring Connections Single Stage Heat PumpTypical Installation YTG-B-0707 YTG-B-0707 Unitary Products Group Copyright by York International Corp . All rights reserved

F*FV, F*FP specifications

York F*FV and F*FP are two advanced HVAC systems designed for commercial and industrial applications, delivering optimized performance and energy efficiency. These models are part of York's commitment to innovative climate control solutions that meet the diverse needs of modern buildings.

The F*FV series is known for its flexible configurations, catering to various indoor environments. This series is engineered with powerful variable-speed fans that adjust airflow according to real-time demand, ensuring not only comfort but also significant energy savings. The integration of advanced inverter technology allows for precise control of compressor speed, which results in lower energy consumption while maintaining stable temperature conditions.

On the other hand, the F*FP series is distinguished by its high cooling and heating capacities, making it suitable for larger facilities such as manufacturing plants and data centers. These systems utilize scroll compressors, which are recognized for their reliability and quiet operation. The F*FP's design prioritizes easy maintenance, with service access points strategically placed to minimize downtime.

Both series utilize advanced refrigerants that comply with environmental regulations, ensuring that users can expect eco-friendly operation. The systems are equipped with intelligent control features, including Wi-Fi connectivity and remote monitoring capabilities. This allows facility managers to oversee operations and make adjustments in real time, leading to enhanced energy management and operational efficiency.

York has equipped both F*FV and F*FP systems with comprehensive diagnostic tools. These features aid technicians in troubleshooting and maintaining the systems, thereby extending their lifespan and ensuring optimal performance. The user-friendly interfaces make it simple for operators to navigate system settings, monitor performance metrics, and receive alerts for maintenance needs.

Notably, both series are designed with robust construction to withstand harsh operating conditions while providing low noise levels, an essential characteristic for environments where minimal disturbance is critical. The systems are also versatile, supporting various installation types, including rooftop, split, and packaged configurations.

In summary, York’s F*FV and F*FP series stand out in the HVAC market, offering a combination of energy efficiency, cutting-edge technology, and ease of use. These systems provide reliable climate control to meet the evolving needs of commercial and industrial spaces, ensuring comfort while promoting sustainability. Whether it’s the versatility of the F*FV or the high capacity of the F*FP, York delivers solutions that enhance productivity and operational effectiveness.