6.7.2Separate fume extraction
min. 10 mm max. 20 mm
Cut: 80mm high 40mm wide
1. Cut an 80mm x 40mm rectangle in the outer wall of the caravan. The position of the cut must be appropriate to the particular model of refrigerator and installation conditions.
2. Connect
(G). Ensure that heat distributor (H) is lodged in the correct position.
3.Insert flue pipe (C) through the aperture.
4.Connect flue pipe (C) to
5.Pack the cut with
6.Screw securing plate (D) into position.
7.Put cap (B) on flue pipe (C).
8.Screw on outer plate (A).
6.8Gas installation
The rules in point 6.1 must be adhered to.
When running on gas, these appliances are intended exclusively to use liquid gas (propane/butane) - under no circumstances should town gas or natural gas be used (EN 27418).
A fixed,
The pressure regulator must concur with the operating pressure specified on the data plate of the appliance. The operating pressure corresponds to the standard pressure of the country of specification (EN 1949, EN 732).
Only one connection pressure is permissible for any one vehicle. A plate showing the permanent, clearly legible notice must be displayed in full view at the point where the gas cylinder is installed.
The gas connection to the appliance must be installed securely and at
zero potential using tube connectors and must be securely connected to the vehicle (a hose connection is not permissible) (EN 1949).
Inflamable material should not be in immediate proximity to the burner.
25