PERFORMANCE DATA SHEETS
Base Grille Water Filtration System
Model T2WG2L/T2RFWG2 Capacity 200 Gallons (757 Liters)
Model T2WG2/T2RFWG2 Capacity 200 Gallons (757 Liters)
System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, Particulate
Class II*; and against NSF/ANSI Standard 53 for the reduction of Mercury,
Benzene, Toxaphene, 
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction  | NSF Reduction  | Average  | Influent Challenge  | Maximum  | Average  | Minimum %  | Average %  | 
Aesthetic Effects  | Requirements  | Influent  | Concentration  | Effluent  | Effluent  | Reduction  | Reduction  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
Chlorine Taste/Odor  | 50% reduction  | 2.0182 mg/L  | 2.0 mg/L ± 10%  | 0.06 mg/L  | 0.0536 mg/L  | 97.03  | 97.34  | 
Particulate Class II*  | 85% reduction  | 1333333 #/mL  | At least 10,000 particles/mL  | 6600 #/mL**  | 2325 #/mL  | 99.51  | 99.83  | 
Contaminant  | NSF Reduction  | Average  | Influent Challenge  | Maximum  | Average  | Minimum %  | Average %  | 
Reduction  | Requirements  | Influent  | Concentration  | Effluent  | Effluent  | Reduction  | Reduction  | 
Lead: @ pH 6.5***  | 0.010 mg/L  | 0.1533 mg/L  | 0.15 mg/L ± 10%  | 0.0005 mg/L  | 0.0005 mg/L  | 99.67  | 99.67  | 
Lead: @ pH 8.5***  | 0.010 mg/L  | 0.1400 mg/L  | 0.15 mg/L ± 10%  | 0.0007 mg/L  | 0.0006 mg/L  | 99.50  | 99.57  | 
Mercury: @ pH 6.5  | 0.002 mg/L  | 0.0058 mg/L  | 0.006 mg/L ± 10%  | 0.0002 mg/L  | 0.0002 mg/L  | 96.54  | 96.54  | 
Mercury: @ pH 8.5  | 0.002 mg/L  | 0.0059 mg/L  | 0.006 mg/L ± 10%  | 0.0005 mg/L  | 0.0003 mg/L  | 91.57  | 94.92  | 
Benzene  | 0.005 mg/L  | 0.0154 mg/L  | 0.015 mg/L ± 10%  | 0.0012 mg/L  | 0.0006 mg/L  | 92.22  | 96.34  | 
0.6 mg/L  | 1.7571 mg/L  | 1.8 mg/L ± 10%  | 0.0250 mg/L  | 0.0066 mg/L  | 98.58  | 99.63  | |
Toxaphene  | 0.003 mg/L  | 0.015 mg/L  | 0.015 mg/L ± 10%  | 0.001 mg/L  | 0.001 mg/L  | 93.33  | 93.33  | 
Carbofuran  | 0.04 mg/L  | 0.0819 mg/L  | 0.08 mg/L ± 10%  | 0.0400 mg/L  | 0.0213 mg/L  | 51.13  | 74.00  | 
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.85 gpm (3.2 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
■It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.
■Use replacement filter T2RFWG2, part #4396841.
2010 suggested retail price of $39.99 U.S.A./$54.95 Canada. Prices are subject to change without notice.
Model T2WG2L: Style 1 – When the filter indicator reads 10%, order a new filter. When the indicator reads 0%, it is recommended that you replace the filter.
Style 2 – When the filter indicator changes from green to yellow, order a new filter. When the indicator changes from yellow to red, it is recommended that you replace the filter.
Style 3 – When the water filter status display changes from “GOOD” to “ORDER,” order a new filter. When the filter indicator reads “REPLACE,” it is recommended that you replace the filter.
Style 4 – Press FILTER to check the status of your water filter. If the filter indicator light is yellow, order a new filter. If the filter indicator light is red, it is recommended that you replace the filter.
Model T2WG2: Change the water filter cartridge every 6 months. If the water flow to the water dispenser or ice maker decreases noticeably before 6 months have passed, replace the water filter cartridge more often.
■These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary.
■The product is for cold water use only.
■Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
■Refer to the “Warranty” section for the Manufacturer’s name, address and telephone number.
■Refer to the “Warranty” section for the Manufacturer’s limited warranty.
Application Guidelines/Water Supply Parameters
Water Supply  | City or Well  | 
Water Pressure  | 30 - 120 psi (207 - 827 kPa)  | 
Water Temperature  | 33° - 100°F (0.6° - 37.8°C)  | 
Service Flow Rate  | 0.85 gpm (3.2 Lpm) @ 60 psi  | 
*Class II particle size: 1 um to <5 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
***Compliant for Lead reduction requirements under NSF/ANSI Standard 53 as tested by Pace Analytical Services, Inc. ® NSF is a registered trademark of NSF International.
13