Whirlpool W10131955C Gas Supply Line, Gas Pressure Regulator, Burner Input Requirements

Page 6

Gas Supply Line

Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the cooktop location. A smaller size pipe on longer runs may result in insufficient gas supply. Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape. With LP gas, piping or tubing size should be ½" minimum. Usually, LP gas suppliers determine the size and materials used in the system.

Flexible metal appliance connector:

If local codes permit, use a ¹⁄₂" or ³⁄₄" I.D. flexible stainless steel tubing gas connector, designed by CSA to connect the cooktop to the rigid gas supply line.

Gas Pressure Regulator

The gas pressure regulator supplied with this cooktop must be used. The inlet pressure to the regulator should be as follows for proper operation:

Natural Gas:

Minimum pressure: 5" (12.7 cm) WCP

Maximum pressure: 7" to 14" (17.8 cm to 35.5 cm) WCP

LP Gas:

Minimum pressure: 11" (27.9 cm) WCP

Maximum pressure: 14" (35.5 cm) WCP

Contact local gas supplier if you are not sure about the inlet pressure.

A ½" male pipe thread is needed for connection to the female pipe threads of the inlet to the cooktop pressure regulator.

Do not kink or damage the flexible metal tubing when moving the cooktop.

Rigid pipe connection:

The rigid pipe connection requires a combination of pipe fittings to obtain an in-line connection to the cooktop. The rigid pipe must be level with the cooktop connection. All strains must be removed from the supply and fuel lines so cooktop will be level and in line.

Must include a shutoff valve:

The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the cooktop opening, such as an adjacent cabinet. It should be in a location that allows ease of opening and closing. Do not block access to shutoff valve. The valve is for turning on or shutting off gas to the cooktop.

B

A

C

A. Gas supply line

B. Shutoff valve “open” position

C. To cooktop

Burner Input Requirements

Input ratings shown on the model/serial rating plate are for elevations up to 2,000 ft (609.6 m).

For elevations above 2,000 ft (609.6 m), ratings are reduced at a rate of 4% for each 1,000 ft (304.8 m) above sea level (not applicable for Canada).

For elevations above 6,560 ft (1999.5 m) a high altitude kit is needed to avoid any reduced power output. See separate LP gas conversion instructions sheet.

Gas Supply Pressure Testing

Gas supply pressure for testing regulator must be at least

1" water column pressure above the manifold pressure shown on the model/serial rating plate.

Line pressure testing above ½ psi gauge (14" WCP)

The cooktop and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa).

Line pressure testing at ½ psi gauge (14" WCP) or lower

The cooktop must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).

†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

6

Image 6
Contents Installation Instructions Cooktop Safety Your safety and the safety of others are very importantInstallation Requirements Tools and PartsLocation Requirements Metal Cooktops Product DimensionsCabinet Dimensions Straight-edge glass cooktopsType of Gas Electrical RequirementsGas Supply Requirements Natural GasGas Pressure Regulator Gas Supply Pressure TestingGas Supply Line Burner Input RequirementsInstallation Instructions Prepare Cooktop for InstallationInstall Cooktop Installing Brackets After Placing Cooktop in Cutout Make Gas ConnectionTo Assemble Pressure Regulator Attach Cooktop to Countertop Typical flexible connectionComplete Connection Check Flame Height Complete InstallationIf the low flame needs to be adjusted Check Operation of Surface BurnersWiring Diagram On 30 76.2 cm modelsOn 36 91.4 cm models Page Sécurité DE LA Table DE Cuisson Votre sécurité et celle des autres est très importanteExigences Dinstallation Exigences demplacementOutillage et pièces Tables de cuisson métalliques Dimensions du produitDimensions du placard Tables de cuisson en verre à bord droitType de gaz Spécifications électriquesSpécifications de lalimentation en gaz Gaz naturelCaractéristiques dalimentation du brûleur Canalisation de gazRégulateur de pression de gaz Test de pressurisation de la canalisation de gazInstallation de la table de cuisson Instructions DinstallationPréparation de la table de cuisson pour Linstallation Style 1 Table de cuisson sur four encastré sous comptoirPlan de travail Bande de mousse Assemblage du détendeur Raccordement au gazRaccordement typique par raccord flexible Compléter le raccordementFixation de la table de cuisson au plan de Travail Vérification de la taille des flammes Achever linstallationContrôle du fonctionnement des brûleurs de surface Si les brûleurs ne sallument pas correctementSchémas DE Câblage Sur les modèles de 30 76,2 cmSur les modèles de 36 91,4 cm W10131955C

W10131955C specifications

The Whirlpool W10131955C is a high-performance refrigerator water filter designed to improve the quality of drinking water and ice produced by Whirlpool refrigerators. This filter is known for its innovative features and reliable technology, ensuring that users enjoy fresh, clean water.

One of the standout characteristics of the W10131955C is its advanced filtration system. It utilizes a combination of activated carbon and other filtration materials to effectively reduce contaminants such as chlorine, lead, and other harmful impurities that can affect water taste and quality. This not only enhances the flavor of the water but also provides peace of mind for households concerned about water safety.

The installation process of the W10131955C is user-friendly, allowing homeowners to replace the filter without the need for any special tools. This tool-free installation is a significant advantage, making it accessible for anyone, regardless of their DIY experience. The filter typically requires replacement every six months or after filtering approximately 200 gallons of water, which helps maintain optimal performance and water quality.

In addition to its filtration capabilities, the W10131955C is designed with compatibility in mind. It is specifically designed for use in several Whirlpool, Maytag, KitchenAid, and Jenn-Air refrigerator models. This ensures that a wide range of users can benefit from its advanced filtration technology, making it a versatile choice for families with different appliances.

The W10131955C filter also features an NSF certification, which indicates that it meets strict safety and performance standards. This certification provides additional assurance to consumers about the filter's effectiveness and reliability.

Moreover, the filter's compact design allows for easy storage and reduces waste, contributing to environmentally-friendly practices. By using the W10131955C, households can minimize bottled water usage, thus reducing plastic waste and promoting sustainability.

Overall, the Whirlpool W10131955C is a top-tier water filter that combines advanced technology with user-friendly features. Its efficient filtration system, easy installation, and compatibility with various refrigerator models make it an essential component for anyone looking to ensure that their drinking water is safe, clean, and delicious.