Whirlpool W10175448A Product Data Sheets, Application Guidelines/Water Supply Parameters

Page 18

PRODUCT DATA SHEETS

Interior Water Filtration System

Model 67003523-750 Capacity 750 Gallons (2839 Liters)

System tested and certified by NSF International against NSF/ANSI

Standard 42 for the reduction of Chlorine Taste and Odor, Particulate

Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead,

Mercury, Atrazine, Toxaphene, Cysts, Turbidity, Asbestos and

Lindane.

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.

Substance Reduction

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum%

Average%

Aesthetic Effects

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Chlorine Taste/Odor

50% reduction

1.88 mg/L

2.0 mg/L ± 10%

0.06 mg/L

0.05 mg/L

96.84

>97.26

Particulate Class I*

85% reduction

5,700,000 #/mL

At least 10,000

69,000 #/mL**

30,583 #/mL

98.94

99.52

 

 

 

particles/mL

 

 

 

 

 

 

 

 

 

 

 

 

Contaminant

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum%

Average%

Reduction

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Lead: @ pH 6.5

0.010 mg/L

0.153 mg/L

0.15 mg/L ± 10%

< 0.001mg/L

< 0.001mg/L

>99.29%

>99.35%

Lead: @ pH 8.5

0.010 mg/L

0.150 mg/L

0.15 mg/L ± 10%

< 0.001mg/L

< 0.001mg/L

>99.29%

>99.33%

 

 

 

 

 

 

 

 

Mercury: @ pH 6.5

0.002 mg/L

0.006 mg/L

0.006 mg/L ± 10%

0.0005 mg/L

0.0003 mg/L

90.91

95.70

Mercury: @ pH 8.5

0.002 mg/L

0.006 mg/L

0.006 mg/L ± 10%

0.0015 mg/L

0.0008 mg/L

75.93

86.22

 

 

 

 

 

 

 

 

Toxaphene

0.003 mg/L

0.015 mg/L

0.015 ± 10%

< 0.001mg/L

< 0.001mg/L

91.67%

92.97%

 

 

 

 

 

 

 

 

Atrazine

0.003 mg/L

0.009mg/L

0.009 mg/L ± 10%

< 0.002 mg/L

< 0.002 mg/L

75.31%

76.99%

 

 

 

 

 

 

 

 

Asbestos

99%

155 MF/L

107 to 108 fibers/L††

< 1 MF/L

< 1 MF/L

>99.99%

>99.99%

 

 

 

 

 

 

 

 

Live Cysts

>99.95%

166,500 #/L

50,000/L min.

< 1 #/L

< 1 #/L

>99.99

>99.99

Turbidity

0.5 NTU

10.7 NTU

11 ± 1 NTU

0.49 NTU

0.31 NTU

95.2

97.09

 

 

 

 

 

 

 

 

Lindane

0.0002 mg/L

0.002 mg/L

0.002 ± 10%

< 0.0001mg/L

0.000 mg/L

96.50%

98.72%

 

 

 

 

 

 

 

 

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C).

It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.

The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. When 90% of the filter’s rated life is used, the yellow (Order) light comes on. When 100% of the filter’s rated life is used, the red (Replace) light comes on, and it is recommended that you replace the filter. For models without filter status lights, replace the filter every 6 months. Use replacement filter model 67003523; order Part Number 4396395.

2007 suggested retail price of $49.99 U.S.A./$65.95 Canada. Prices are subject to change without notice.

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

Refer to the “Water Filtration System” section for the Manufacturer’s name and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited warranty.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

35 - 120 psi (241 - 827 kPa)

Water Temperature

33° - 100°F (1° - 38°C)

Service Flow Rate

0.78 gpm (2.9 L/min.) @ 60 psi.

 

 

*Class I particle size: >0.5 to <1 um

**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.

These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions. ††Fibers greater than 10 um in length

Based on the use of Cryptosporidium parvum oocysts ® NSF is a registered trademark of NSF International.

18

Image 18
Contents Refrigerator Safety Refrigerator User InstructionsUnpack the Refrigerator Installation InstructionsClean Before Using Before You Throw Away Your Old Refrigerator or FreezerWater Supply Requirements LocationRequirementsElectrical Requirements Recommended Grounding MethodConnect the Water Supply Complete the Installation Refrigerator Doorsand DrawerStyle 2-French Doors Remove Door and Hinges Style 1-Standard DoorReverse Door Standard Door optional Remove Drawer Front Replace Door and Hinges Style 1-Standard DoorRemove and Replace Freezer Drawer Replace Drawer FrontDoor Swing Reversal optional Standard Door Freezer DoorStandard Door Freezer Drawer Hinge ScrewsDoor Removal & Replacement Adjust the Door Style1-Freezer Door ModelsStyle 2-Freezer Drawer Models Using the Controls Refrigerator USEOpening and Closing Doors Crisper Humidity Control Ice MakerWater Dispenser Water FiltrationSystem CleaningRefrigerator Care Changing the Light BulbRefrigerator will not operate TroubleshootingRefrigerator Operation Motor seems to run too muchTemperature and Moisture Ice and WaterWater dispenser will not operate properly Water is leaking from the dispenser systemWater from the dispenser is warm Product Data Sheets Application Guidelines/Water Supply ParametersThis limited warranty does not cover Limited WarrantyItems Excluded from Warranty Disclaimer of Implied Warranties Limitation of RemediesSécurité DU Réfrigérateur RéfrigérateurInstructions D’INSTALLATION Exigences demplacementDéballagedu réfrigérateur Spécifications del’alimentationen eau Méthode recommandée de mise à la terreSpécificationsélectriques Pression de leauRaccordement de la canalisation deau Raccordement à une canalisation d’eauRaccordement au réfrigérateur Style 2-Porte à deux battants Achever l’installationPorteset tiroir du réfrigérateur Dépose des portes et des charnières Style-1 Porte standardPorte du compartiment de réfrigération Modèles de compartiments de congélation avec porteCaisse Porte du compartiment de congélationRéinstaller la façade du tiroir Réinstallation Porte et charnières Style 1-Porte standardRetirer et réinstaller le tiroir du congélateur Style 2-Portes à deux battantsInversion du sens douverture des portes option Porte standard Porte du compartiment de congélationVis de charnière Dépose et réinstallation des portes Portes à deux battantsAjustement de la porte Style 1-Modèles de compartiments de congélation avec porteStyle 2-Modèles de compartiments de congélation avec tiroir Utilisation des commandes Utilisation DU RéfrigérateurOuvertureet fermeture des portes Mise en marche/arrêt de la machine à glaçons Machine à glaçonsDistributeur d’eau Taux de production des glaçonsEntretien DU Réfrigérateur NettoyageSystème de filtrationde leau Remplacement de l’ampoule d’éclairage Dépannage Fonctionnement du réfrigérateurLa température est trop élevée Température et humiditéGlaçons et eau Il y a une accumulation dhumidité à lintérieurLe distributeur deau ne fonctionne pas correctement Leau du distributeur est tièdeFeuilles DE Données SUR LE Produit Système de filtration d’eau intérieurArticles Exclus DE LA Garantie Garantie DES Gros Appareils Ménagers Whirlpool CorporationGarantie Limitée La présente garantie limitée ne couvre pasW10175448A SP PN W10175487A Whirlpool Corporation All rights reserved