Bryant Comprehensive Guide to ERV and HRV Installation, Wiring, and Controls

Page 5

thermostat and follow same guidelines as installing a thermostat (locate approximately 5 ft (1.5m) above floor, mount on an inside partitioning wall, etc.)

Wiring

Remove top cover assembly from wall control and pass thermostat wire through hole located on back of control before attaching to wall. Connect Y, R, G, and B (yellow, red, green, and black) between wall control and ERV/HRV connector following color code. (See Fig. 5 and 10.) Replace top cover assembly.

NOTE: ERV/HRV wall control and circuit board operate on 12VDC.

 

 

YELLOW

 

 

RED

 

 

GREEN

 

 

BLACK

Y

R

GB

A98383

Fig. 10 - Typical Wall Control

Operation

The Standard and Latent wall controls have 4 basic modes of operation, OFF, LOW, HIGH, and INTERMITTENT. Be sure that all modes of operation are fully functional. See Table 1 indicating standard control operation.

1.With switch off, ERV/HRV is inoperative and the LED is out.

2.With switch on LOW, ERV/HRV continuously exchanges air with outside. If control is satisfied, blower will run in low speed, otherwise, blower will run on high speed. The LED is illuminated all the time.

3.With switch on INTERMITTENT, the ERV/HRV ex- changes air with outside on high-speed blower, and unit shuts down when control is satisfied. The ON LED is illu- minated all the time, and AIR EXCHANGE LED is illumi- nated only when unit is running.

Humidity Selector

The humidity selector is a built-in control designed to properly control the level of humidity in the house during the winter and summer months. This control helps avoid condensation problems in upper northern regions where indoor humidity is a problem during the winter season.

NOTE: This control is not to be confused with a dehumidistat used during the summer months to control high relative indoor humidity.

Table 2 recommends humidity levels to avoid condensation.

OneTouch Control

The OneTouch Control can be used as the primary wall control for the ERV/HRV. This control will step through the modes of operation with consecutive presses of the button. The LED indicates which mode is currently selected, Off, Intermittent, Low, or High.

NOTE: OneTouch Control does not have a humidity selector.

NOTE: OneTouch Intermittent mode exchanges air on low speed for 20 minutes per hour.

Latent Control

NOTE: For Latent Controls used with ERV;s, to ensure highest degree of humidity control in cooling season, the INTERMITTENT mode should be used.

Integrated Control

All units are equipped with an integrated control, located under the unit, in front of the electrical compartment. Use the push button (1) to control the unit. The LED (2) will then shows on which mode the unit is in. Integrated Control overrides Wall Control function. When LED is off, ventilator responds to Wall Control command. See Fig. 11.

WARNING

AVERTISSEMENT

Risk of electric shock. Before performing

Danger d’électrocution. Débranchez

any maintenance or servicing, always

toujours l’appareil avant d’entreprendre

disconnect the unit from its power source.

des travaux d’entretien ou de réparation.

 

CAUTION

ATTENTION

 

Unscrew both screws to open the electrical

Dévisser les deux vis pour ouvrir le compartiment

 

compartment. To completely remove, detach

électrique. Pour retirer complètement, le

 

from its retention wire inside.

détacher de son fil de rétention intérieur.

No light

OFF or remote controled

 

Amber light

LOW speed

 

Green ligh

HIGH speed

 

Blinking light

See User Manual

 

Sans lumière

Arrêté ou contrôlé

 

 

par contrôle mural

 

Lumière ambre

Basse vitesse

 

Lumière verte

Haute vitesse

 

Clignotant

Voir guide d’utilisation

 

1

 

2

A07260

Fig. 11 - Integrated Control

Refer to table below to see how to operate the unit using its integrated control.

PRESS ON PUSH

LED COLOR

RESULTS

BUTTON

 

 

 

 

 

Once

Amber

Unit is on Low

Speed

 

 

 

 

 

Twice

Green

Unit is on High

Speed

 

 

 

 

 

Three Times

No Light

Unit is OFF

If a problem occurs during the unit operation, its integrated control LED (2) will blink. The color of the blinking light depends on the type of error detected. Refer to Troubleshooting for further details.

NOTE: The ERV/HRV may be controlled using the Evolution system control. The ERV/HRV may be connected using either a NIM or a 4-Zone Damper Module. See the appropriate instructions if using the NIM or a 4-Zone Damper Module for connection instructions.

The Evolution system control will simultaneously control the ERV/HRV and the indoor blower.

Push Button Timers may be used and are connected to the ERV/HRV. However, the Evolution system should be set to continuous fan to ensure that the fresh air is circulated in the home. In a Zoned System, at least one zone should be set to continuous fan.

OPERATING THE ERV/HRV WITH

THE EVOLUTION CONTROL

The ventilator has four settings in heating mode and three settings in cooling mode.

Heating:

AUTO - the ventilator selects the speed based on indoor humidity and outdoor temperature. It may cycle on/off every 30 minutes depending on humidity and outside temperature.

LOW - low speed all of the time. HIGH - high speed all of the time.

ERV / HRV

5

Image 5
Contents Introduction Table of ContentsSafety Considerations Component Description Installation ConsiderationsUnit Installation Carbon Monoxide Poisoning Hazard Independent System ApplicationForced-Air Application Wall Control Operating the ERV/HRV with Evolution Control Electrical Connections AccessoriesMagnehelic gauge placement Balancing Procedure Set the unit to high speedBalancing ERV/HRV Move tubing to Fresh air flow pressure tapsControl Board Operation Care and MaintenanceVentilation Evaluation CUT Hazard TroubleshootingElectrical Shock Hazard LED flashes Green Thermistor error TroubleshootingERV Defrost Cycles HRV Defrost CyclesERV / HRV Wiring Diagram Logic Diagram