2. CONTROLS (CONT’D)

2.3.2USING 40425 CONTROLLER (CONTD)

RECIRCULATION MODE (RE-CIRC)

OFF MODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The unit recirculates air. However, every hour, the unit exchanges air for 6 minutes so that

it can obtain a reading

of the outdoor temperature*.

The unit is off.

The outdoor temperature*

is not displayed.

AUTOMATIC MODE (AUTO)

Off in

Air recirculation

Air exchange in

Auto mode

in Auto mode

Auto mode

The unit operates on a 60-minute cycle. For the first 40 minutes, the unit recirculates air or is off (See configuration parameter 2 in Section 2.3.3). For the last 20 minutes, it exchanges air. However, if the outdoor temperature* is too high or too low (see configuration parameters 3 and 4 in Section 2.3.3), the unit recirculates air during the last 20 minutes.

*The outdoor temperature reading is taken from the unit FRESH AIR FROM OUTSIDE port; due to the lenght of the insulated duct, the reading is slightly different from the real outside temperature.

- 7 -

Image 7
Contents GSVH1K About this Manual Table of Contents About These Units Boost Controls40425 Controls CONT’DUsing 40425 Controller CONT’D AU / on Maintenance Maintenance CONT’D GSEH3K energy recovery core cannot be washed with water Optional ALPINE/PINE Filter Troubleshooting WHOLE-HOUSE AIR Filtration System Warranty