Broan GSFH1K, GSVH1K, GSHH3K, GSEH3K user manual AU / on

Page 8

2. CONTROLS (CONT’D)

2.3.340425 WALL CONTROLLER CONFIGURATION

See the configuration table below for the list of configuration parameters. Press the Menu button for 3 seconds to enter or exit the configuration menu.

NOTE: The wall control automatically saves any changes and exits the configuration menu if no button is pressed within the next 60 seconds.

Press the Menu button briefly to advance to the next parameter (menu number). Press the or button to change the parameter setting.

CONFIGURATION TABLE

MENU

PARAMETER

OPTIONS

DEFAULT

DESCRIPTION

NUMBER

 

 

SETTING

 

 

 

 

 

 

1

TEMPERATURE

°C / °F

°C

SELECTS BETWEEN °C AND °F DISPLAY.

FORMAT

 

 

 

 

 

 

 

 

 

 

AUTO MODE

 

 

SELECTS BETWEEN AIR RECIRCULATION

2

RE / OF

RE

(RE) AND OFF (OF).

OPERATION

 

 

 

SEE SECTION 2.3.2.

 

 

 

 

 

 

 

 

 

 

AUTO MODE

 

 

PREVENTS AIR EXCHANGE IN AUTO

3

LOW

-30°C TO 0°C

(-25°C)

MODE IF THE OUTDOOR TEMPERATURE

TEMPERATURE

(-22°F TO 32°F)

(-13°F)

IS TOO LOW.

 

 

LIMIT

 

 

SEE SECTION 2.3.2.

 

 

 

 

 

 

AUTO MODE

 

 

PREVENTS AIR EXCHANGE IN AUTO

4

HIGH

0°C TO 30°C

(27°C)

MODE IF THE OUTDOOR TEMPERATURE

TEMPERATURE

(32°F TO 86°F)

(81°F)

IS TOO HIGH.

 

 

LIMIT

 

 

SEE SECTION 2.3.2.

 

 

 

 

 

 

 

 

 

AU: THE SCREEN ILLUMINATES FOR 12

5

BACKLIGHT

AU / ON

AU

SECONDS WHEN ANY KEY IS PRESSED

MODE

ON: THE SCREEN IS PERMANENTLY

 

 

 

 

 

 

 

ILLUMINATED.

 

 

 

 

 

- 8 -

Image 8
Contents GSVH1K About this Manual Table of Contents About These Units Controls BoostControls CONT’D 40425Using 40425 Controller CONT’D AU / on Maintenance Maintenance CONT’D GSEH3K energy recovery core cannot be washed with water Optional ALPINE/PINE Filter Troubleshooting Warranty WHOLE-HOUSE AIR Filtration System