1. ABOUT THESE UNITS

!WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S) OBSERVE THE FOLLOWING:

1.This unit is intented for residential installation only.

2.Installation must be done in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

3.This unit is not designed to provide combustion and/or dilution air for fuel-burning appliances.

4.Do not install in a cooking area or connect directly to an appliance.

5.Before replacing filters, servicing or cleaning unit, disconnect the power cord from the electrical outlet.

6.When cutting or drilling into the wall or ceiling, do not damage electrical wiring or other hidden utilities.

7.Do not use this unit with any solid-state speed control device other than wall controls ACCGSC1 or 40425, provided with the unit.

8.This unit must be grounded. The power supply cord has a 3-prong grounding plug for your personal safety. It must be plugged into a mating 3-prong grounding receptacle, grounded in accordance with the national electrical code and local codes and ordinances. Do not remove the ground prong. Do not use an extension cord.

9.This unit must be installed in a weatherized location out of direct sunlight and protected from the elements.

10.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in this document.

11.When cleaning the unit, it is recommended to wear safety glasses and gloves.

CAUTION

1.For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

2.Intended for residential installation in accordance with the requirements of NFPA 90B.

3.For GSVH1K, GSHH3K and GSEH3K units only: Be sure to duct air outside. Do not intake / exhaust air into spaces within walls or ceiling or into attics, crawl spaces, or garage.

4.Do not run any air ducts directly above or closer than 2 ft (0.61 m) to any furnace or its supply plenum, boiler, or other heat producing appliance. If a duct has to be connected to the furnace return plenum, it must be connected not closer than 2 ft (0.61 m) from this plenum connection to the furnace.

5.The ductwork is intended to be installed in compliance with all local and national codes that are applicable.

6.To avoid prematurate clogged filters, turn OFF the unit during construction or renovation.

7.At least once in a year, the unit mechanical and electronic parts should be inspected by qualified service personnel.

8.Please read the unit specification label on the product for further information and requirements.

-4 -

Image 4
Contents GSVH1K About this Manual Table of Contents About These Units Controls BoostControls CONT’D 40425Using 40425 Controller CONT’D AU / on Maintenance Maintenance CONT’D GSEH3K energy recovery core cannot be washed with water Optional ALPINE/PINE Filter Troubleshooting Warranty WHOLE-HOUSE AIR Filtration System