IMPORTANT:

The extractor is intended to be mounted directly to the ceiling using fixings appropriate for the ceiling. Ensure that there is adequate ceiling strength and supports at the fixing points; if in doubt, consult a joiner or electrician.

When the extractor is to be installed above an electric hob, the minimum distance between the hob and extractor must exceed 600mm (650mm is recommended).

When the extractor is to be installed above a gas hob, the minimum distance between the hob and extractor must exceed 700mm (750mm is recommended).

If the instructions provided with your gas hob state that the required distance between the hob and extractor must be greater than 700mm, then that is the distance that should be observed; this is a legal requirement and may lead to your hob being disconnected from the gas supply and the installation being reported to RIDDOR (The height should be measured from the top of the burners).

IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE GAS HOB, THE MINIMUM DISTANCE BETWEEN THE HOB AND EXTRACTOR MUST BE AT LEAST 760mm.

The width of any hob must not be greater than the width of the extractor installed above it. Fig. 3

Ducting and Ventilation

We recommend the use of ducting with a diameter of 150mm. Ducting with diameters of 100mm or 120mm may be used, but performance will be reduced.

318

57

Gas:Gas:750mmrecommmended. .

Electric:650mmrecommmended. .

Fig. 3

7

Image 8
Contents EVPK9 Linear Extractor Please note Appliance informationCE Declarations of Conformity Using your Extractor Care and Maintenance CleaningCleaning the grease filter Changing the charcoal filter re-circulating onlyChanging the Light Mains Electricity Connection Blue = NEUTRAL, Brown = LiveTroubleshooting Total rated power consumptionElectrical Information If your extractor is not workingMounting your Extractor Ducting and VentilationInstallation To mount your extractor to the ceilingInstallation Installation Installation Page Page Page Customer Care Department 01949 862