CDA EVCK4 manual Important Note

Page 11

Mounting your extractor

IMPORTANT NOTE:

The extractor is now mounted and secured to the wall; the electrical connections are now required to be made in order for the extractor to function.

1.Ensure that there are no trapped wires - The mains lead and control wires are easily trapped when securing the stainless section to the motor.

2.Locate the main terminal box (on the left as you look at it) and remove the 2 screws, shown as D on the diagram below. Connect the main connector plug (Shown as B in the diagram) and replace the cover.

3.Locate the control terminal box (on the right) and remove the 2 screws. Connect the connector as shown in the diagram (A) and refit the terminal cover.

Fig. 16

10

Image 11
Contents EVCK4 Cylinder Extractors Please note Appliance informationCE Declarations of Conformity Using your Extractor Changing the charcoal filter re-circulating only Care and MaintenanceCleaning Cleaning the grease filterChanging the Light If your extractor is not working Total rated power consumptionMains Electricity Connection Installation Mounting your extractor Mounting your extractor Mounting your extractor Important Note Customer Care Department 01949 862