CDA EVCK4 manual Installation

Page 7

Installation

IMPORTANT:

The extractor is intended to be mounted directly to the ceiling using fixings appropriate for the ceiling. Ensure that there is adequate ceiling strength and supports at the fixing points; if in doubt, consult a joiner or electrician.

Your extractor can be used to filter and recycle the air within your kitchen (A), or to extract the air outside (B). When extracting air to the outside, the unit can be vented as shown in the diagram below. Note that we recommend the use of ducting with a diameter of 150mm. Ducting with diameters of 100mm or 120mm may be used, but performance will be reduced.

When installing this appliance over a CDA hob, the clearance between the extractor and the hob must be equal to or exceed 650mm. This instruction overrides the instructions supplied with the CDA hob. (The height should be measured from the top of the hotplates or burners)

Where the extractor is to be installed above a non-CDA hob, the instructions supplied with the hob may dictate that the height required above the hob is greater than 650mm.

IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE HOB, THE MINIMUM DISTANCE BETWEEN THE HOB AND EXTRACTOR MUST BE AT LEAST 760mm.

Fig. 6

650mm

Fig. 7

6

Image 7
Contents EVCK4 Cylinder Extractors CE Declarations of Conformity Appliance informationPlease note Using your Extractor Changing the charcoal filter re-circulating only Care and MaintenanceCleaning Cleaning the grease filterChanging the Light Mains Electricity Connection Total rated power consumptionIf your extractor is not working Installation Mounting your extractor Mounting your extractor Mounting your extractor Important Note Customer Care Department 01949 862