Cannon 10588G, 10582G, 10585G, 10583G, 4866200152-01 Technical Data Dimensions

Page 25

INSTALLATION INSTRUCTIONS

TECHNICAL DATA

DIMENSIONS

Height

900 - 915mm

Width

600mm

Depth

595mm (excluding door handles)

GENERAL

Gas connection

Rp 1/2 (1/2” BSP female)

Pressure test point

Hotplate burner injector.

Gas rate adjustment

None

Aeration adjustment

None

Electrical connection

4mm2 twin and earth.

 

230-240V a.c. 50Hz.

 

 

HOTPLATE

3.0kW (220g/h)

Front left and rear right

 

 

 

HOTPLATE

1.8kW (130g/h)

Front right and rear left

 

 

 

GRILL

2.4 / 2.6kW

 

 

TOP OVEN

1.7 / 1.85kW

 

 

MAIN OVEN

2.3 / 2.5kW

 

 

25

Image 25
Contents Henley Contents Introduction Always For Your SafetyFor Your Safety Automatic Cooking Timer OperationGuidance on Automatic Cooking Clockface Setting the Time of DAY Auto Cooking Programmes Timer Operation Other Notes on Timer Operation To USE the Hotplate HotplateHOW to Deal with a FAT Fire Safety Requirements for Deep FAT FryingGrill PAN Handle GrillTo USE the Grill TOP Oven Conventional Cooking OvensTo USE the TOP Oven Main Oven FAN CookingOven Cooking Chart Oven Preparing Food for Slow Cooking ‘SLOW COOK’ SettingOven Heat Clean Linings Care and CleaningReplacement of Oven Light Bulb Cooker Finish Cleaning Method Care and CleaningDrop Down Doors Side Opening DoorsSomething Wrong With Your Cooker Problem CheckDisposal of Your Product Installation Instructions Technical Data Dimensions Space for Fixing Levelling Electrical Installation Page Page Page Key Contacts