INSTALLATION INSTRUCTIONS

Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure) and the adjustment conditions are compatible. The adjustment conditions for this appliance are stated on the data badge which is fitted on the back panel.

This appliance is not designed to be connected to a combustion products evacuation device. It must be installed and connected in accordance with current installation regulations. particular attention should be given to the relevant requirements regarding ventilation.

MODEL NUMBERS 10560G, 10562G and 10565G

Category I2H (GB. IE)

These models are set to burn NATURAL GAS (G20) at 20 mbar ONLY and can not be used on any other gas.

MODEL NUMBER 10566G

Category I3+ (GB. IE)

These models are set to burn PROPANE GAS (G31) at 37 mbar and BUTANE GAS (G30) at 28-30 mbar

GAS SAFETY (INSTALLATION & USE) REGULATIONS

It is the law that all gas appliances are installed by competent persons in

accordance with the current edition of the above regulations. It is in your interest and that of safety to ensure compliance with the law.

In the UK, CORGI registered installers work to safe standards of practice. The cooker must also be installed in accordance with BS 6172.

Failure to install the cooker correctly could invalidate the warranty liability claims and could lead to prosecution.

LOCATION

The cooker may be located in a kitchen, kitchen/diner or a bed-sitting room, but not in a room containing a bath or shower. The cooker must not be installed in a bed-sitting room of less than 20m3.

LPG Models shall not be installed in a room or internal space below ground level, e.g. in a basement.

PROVISION FOR VENTILATION

The room containing the cooker should have an air supply in accordance with BS 5440: Part 2.

The room must have an opening window or equivalent; some rooms may also require a permanent vent. If the room has a volume between 5 and 10m3, it will require an air vent of 50cm2 effective area unless it has a door which opens directly to outside. If the room has a volume of less than 5m3, it will require an air vent of 100cm2 effective area. If there are other fuel burning appliances in the same room, BS 5440: Part 2 should be consulted to determine air vent requirements.

22

Image 22
Contents Woburn Contents Introduction Replacing a BatteryDisposal of Your Product For Your Safety Please read the precautions below before using your cookerFor Your Safety Hotplate To USE the HotplateSafety Requirements for Deep FAT Frying HOW to Deal with a FAT FireTo USE the Grill GrillGrill PAN and Handle Relighting the BurnerShelf Position Food High PositionMain Oven To USE the Main OvenStorage and RE-HEATING of Food Cold Start CookingRoasting of Large Poultry ‘COOK CHILL’ DishesMain Oven Cooking Chart Meat and PoultryYeast Mixtures ‘SLOW COOK’ Setting Using the ‘SLOW COOK’ Setting for Slow CookingTOP Oven Guidance on Using the TOP OvenTo USE the TOP Oven TOP Oven Cooking Chart Gas Shelf Food Care and Cleaning Main Oven Heat Clean LiningsCooker Finish Cleaning Method Remove the door inner glass as follows Side Opening DoorsDrop Down Doors Refit the door inner glass as followsProblem Check Something Wrong With Your CookerModel Number 10566G Installation InstructionsGAS Safety Installation & USE Regulations LocationGeneral Technical Data DimensionsNatural GAS LPG Models Space for Fixing Cooker HoodsLevelling Unpacking the CookerStability Bracket Connecting to GAS Supply Installation and Operational Checks Key Contacts