INSTALLATION INSTRUCTIONS

Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure) and the adjustment conditions are compatible. The adjustment conditions for this appliance are stated on the data badge which is fitted on the rear panel.

This appliance is not designed to be connected to a combustion products evacuation device. It must be installed and connected in accordance with current installation regulations. Particular attention should be given to the relevant requirements regarding ventilation.

MODEL NUMBERS 10520G and 10525G

Category I2H (GB, IE)

These models are set to burn NATURAL GAS (G20) at 20 mbar ONLY and cannot be used on any other gas.

MODEL NUMBERS 10526G

Category I3+ (GB, IE)

These models are set to burn PROPANE GAS (G31) at 37 mbar and BUTANE gas (G30) at 28 - 30 mbar and can not be used on any other gas.

GAS SAFETY (INSTALLATION & USE) REGULATIONS

It is the law that all gas appliances are installed by competent persons in accordance with the current edition of the above regulations. It is in your interest and that of safety to ensure compliance with the law.

In the UK, CORGI registered installers work to safe standards of practice.

The cooker must also be installed in accordance with BS 6172. Failure to install the cooker correctly could invalidate the warranty liability claims and could lead to prosecution.

LOCATION

The cooker may be located in a kitchen, kitchen/diner or a bed-sitting room, but not in a room containing a bath or shower. The cooker must not be installed in a bed-sitting room of less than 20m3.

LPG models must not be installed in a room or internal space below ground level, e.g. in a basement.

PROVISION FOR VENTILATION

The room containing the cooker should have an air supply in accordance with BS 5440:Part 2.

The room must have an opening window or equivalent; some rooms may also require a permanent vent. If the room has a volume between 5 and 10m3, it will require an air vent of 50 cm2 effective area unless it has a door which opens directly to outside. If the room has a volume of less than 5m3, it will require an air vent of 100 cm2 effective area. If there are other fuel burning appliances in the same room, BS 5440: Part 2 should be consulted to determine air vent requirements.

18

Image 18
Contents Worcester Contents Introduction For Your Safety AlwaysFor Your Safety Hotplate To USE the HotplateSafety Requirements for Deep FAT Frying HOW to Deal with a FAT FireGrill To USE the GrillOven To USE the OvenRelighting the Burner Storage and RE-HEATING of Food Cold Start CookingRoasting of Large Poultry ‘COOK CHILL’ DishesOven Cooking Chart Meat and PoultryYeast Mixtures ‘SLOW COOK’ Setting Using the ‘SLOW COOK’ Setting for Slow CookingStorage Compartment Disposal of Your ProductCare and Cleaning Oven Heat Clean LiningsReplacement of Oven Light Bulb Cooker Finish Cleaning Method Vitreous EnamelProblem Check Something Wrong With Your CookerModel Numbers 10526G Installation InstructionsGAS Safety Installation & USE Regulations LocationTechnical Data Dimensions GeneralSpace for Fixing Cooker HoodsLevelling Connecting to GAS SupplyUnpacking the Cooker Stability BracketElectrical Connection Connect to a 230-240V A.C. Supply onlyInstallation and Operational Checks Key Contacts

10520G, 10525G, 10526G specifications

The Cannon 10525G, 10526G, and 10520G are part of a sophisticated line of printers that push the envelope in digital printing technology. These models are designed for high performance, catering to both business and professional environments where quality and efficiency are paramount.

One of the standout features of these printers is their advanced print resolution. With a maximum resolution that can reach up to 2400 x 1200 dpi, users can expect crisp, clear images and sharp text, suitable for marketing materials, presentations, and other professional documents. This level of detail is bolstered by innovative print head technology that utilizes precise ink placement and advanced droplet technology.

The 10525G and 10526G models are particularly noted for their speed, with print speeds that can reach up to 32 pages per minute for color documents and even faster for black-and-white prints. This speed is complemented by automatic duplex printing, which allows users to print on both sides of the paper without manual intervention, significantly reducing both paper consumption and time spent on printing tasks.

Another significant aspect of these devices is their connectivity options. They support various means of connectivity, including USB, Ethernet, and Wi-Fi, enabling seamless integration into any office setup. The built-in mobile printing capabilities allow users to print directly from smartphones and tablets through services like Apple AirPrint and Google Cloud Print, enhancing convenience in a mobile-driven world.

Energy efficiency is another hallmark of the Cannon 10520G series. These models are designed to comply with energy star certification, reducing the overall energy costs for users while minimizing their environmental footprint. Features such as “Quiet Mode” further enhance usability in shared spaces, providing a quieter operation without sacrificing quality or speed.

In terms of usability, the user-friendly interfaces on these printers facilitate easy navigation through the various functions. Features like to preview print jobs and individual job management enhance operational efficiency, making it effortless for users to manage their printing tasks.

Overall, the Cannon 10525G, 10526G, and 10520G combine cutting-edge technology with robust features, making them excellent choices for anyone in need of reliable, high-quality printing solutions in both office and professional environments. Their blend of speed, quality, and efficiency showcases Canon's commitment to innovation and excellence in the printing industry.