DeLonghi EUROCHEF - PRO Hang Hood On Wood Bracket, Test Duct Cover Fit do not install Duct covers

Page 10

EUROCHEF - PRO WALL HOOD

STEP 3A: INSTALL HOOD ONTO WALL (see enclosed template)

SKIP THIS STEP IF INSTALLING BENEATH A SOFFIT OR CABINET, GO TO STEP 3B.

Affix enclosed paper template to wall.

From the line indicating the bottom of the hood, measure 17” up and draw another line for the location of the Wood Bracket. See illustration.

Locate at least 2 vertical studs at the Wood Bracket.

Center the supplied Wood Bracket, left to right and below the marked line.

Insert hood mounting screws in the Wood Bracket at the locations shown in the diagram, so screws protrudes 1/4". This 1/4” gap will provide clearance to hang the hood.

IMPORTANT: FRAMING MUST BE CAPABLE OF SUPPORTING UP TO 150 LBS

Secure the Wood Bracket to 2 or more vertical studs, using at least 2 of the 4 supplied long screws.

IMPORTANT: Screws must penetrate at least 1-1/2" into verti- cal studs. Countersink screws into support.

AFFIXING THE HOOD MOUNTING SCREWS

 

x

 

 

 

 

24”

8”

 

 

 

 

30”

11”

2”

 

 

 

36”

14”

 

 

 

 

x

48”

20”

 

 

 

 

x

 

5/16”

 

 

 

1

 

 

 

 

 

Original Mounting

 

 

 

 

 

 

Screws as Shipped

Hang Hood On Wood Bracket

Lift the hood and hold close to the installation location. Route house wiring through the knockout and into the junction box.

Place the hood over the Wood Bracket. Be sure the mount- ing screws engage the keyhole slots in the back of the hood.

Check to be sure the hood is level and centered.

Use midpoint arrow in back of hood to confirm horizontal position.

24

Centerline of

Installation Space

 

Test Duct Cover Fit (do not install Duct covers)

Place duct covers or recirculating cover over the top of the hood to check for gaps.

Confirm that the ceiling gap, if any, is less then 3/8”.

If gap is greater than 3/8", OR if duct covers do not fit, it is necessary to remove, re-measure and reinstall the Wood Bracket.

10

 

Air-2

 

Image 10
Contents Eurochef PRO Wall Hood Read and Save These InstructionsEurochef PRO Wall Hood HoodsRead These Instructions Completely and Carefully Contents and page Number Product DimensionsUsing Duct Cover Accessories Advance PlanningRemove the Rangehood Parts ProvidedFor Ducting Through Wall Please see Template Determine HOOD, Ductwork and Wiring LocationsPrepare Hood for Installation Junction BOX LocationBlower Position Option Blower Position ChartHood size Motor Blower Upgrade KIT 30 and 36 Hoods If Changing Blower Position Security ScrewTest Duct Cover Fit do not install Duct covers Hang Hood On Wood BracketAlternate Mounting Method Skip this Step if Using Wall Mounting MethodMount Hood onto Soffit or Cabinet Verify that power is turned off at the source Install Duct Covers Connect ElectricalConnect Ductwork RE-INSTALL the Filter Frame Tighten Hanging ScrewsInstall Filter Test Function of Hood Warranty Cleaning FiltersCleaning Hood Care and USE Replacing Halogen BulbEurochef U.S.A