Blodgett B48-RAD, B48-NFR, B36-RAD, B36-NFR manual Attach Countertop Legs, Connect GAS Supply

Page 16

INSTALLATION

INFRARED/RADIANT COMPACT BROILER

STEP 2C: ATTACH COUNTERTOP LEGS

1.Install each leg by screwing them into the threaded holes in the bottom of the base.

2.Stand the broiler on its legs and position to minimum clearances specified on serial tag.

Figure 6

Attaching Legs for Countertop Infrared/Radiant Compact Broiler

STEP 3: CONNECT GAS SUPPLY

If this equipment is being installed at over 2,000 feet altitude and that information was not specified when ordered, contact the appropriate authorized Blodgett Range Service Representative or the Blodgett Range Service Department. Failure to install with proper orifice sizing will result in poor performance and may void the warranty.

The broiler is design-certified for operation on natural or propane gases. The broiler is shipped configured and adjusted for the type of gas specified by the purchaser, which is indicated on the serial plate (see Figure 1 on page 3). Connect the broiler ONLY to the type of gas for which it is configured and adjusted.

The Infrared/Radiant Compact Broiler mounts on the flue riser of a range, and either will have a 3/8" rear gas connection (with a 3/8" male NPT connector) extending through the rear of the flue riser (see Figure 2 on page 5), or will have the optional internal-piping to the front-manifold of the range.

For wall-mount and countertop models, the gas connection (3/8 NPT) extends directly out the rear of the broiler (near the bottom-right-rear corner), or (using an elbow) out the top of the broiler near the top-right-rear corner.

Minimum supply pressure is 7" W.C. for natural gas, 11" W.C. for propane. An internal pressure regulator and shutoff valve are provided. If using a flexible-hose gas connection, the I.D. of the hose must not be smaller than the connector on the broiler, and must comply with ANSI Z21.69. Provide an adequate means of restraint to prevent undue strain on the gas connection.

If applicable, the vent line from the gas appliance pressure regulator must be installed to the outdoors in accordance with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1,or the Propane Installation Code CAN/CGA-B149.2,as applicable.

An adequate gas supply is imperative. Undersized or low-pressure lines will restrict the volume of gas required for satisfactory performance. Fluctuations of more than 25% on natural gas or 10% on propane gas will create problems and affect burner-operating characteristics. A 1/8" pressure tap is located on the manifold to measure the manifold pressure. The supply line to the broiler should be no smaller than the inside diameter of the pipe on the broiler to which it is connected.

PAGE 16 OF 24

INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)

Image 16
Contents Infrared/Radiant Compact Broiler Fire Hazard For Your Safety Burn HazardExplosion and Asphyxiation Hazard Electric Shock HazardIntroduction Location of Serial PlateMinimum Clearances from Combustible Construction SpecificationsClearances Dimensions Ventilation GAS SupplyINFRARED/RADIANT Compact Broiler Cleaning & Maintenance Operation Explosion HazardLighting After GAS has Been Shut OFF Broiler OperationOperation of Infrared Compact Broiler Lighting Broiler Pilots Shutdown of BroilerCleaning & Maintenance Daily Cleaning and MaintenanceMonthly Cleaning and Maintenance Semiannual Cleaning and MaintenanceSTAINLESS-STEEL Surfaces Immediately Inspect for Shipping Damage InstallationUnpacking Mounting of Infrared/Radianr Compact Broiler on Flue-Riser Mount on Flue Riser of RangeMount on Wall Attach Countertop Legs Connect GAS SupplyInstallation of Sloped Enclosure If Ordered Install Sloped Enclosure Optional AccessoryWIPE-CLEAN and SHUT-DOWN Appliance Check the InstallationCheck Broiler Operation Service TroubleshootingAccess to Serviceable Parts Access to Serviceable PartsAdjustment of Broiler Pilots Adjustment of LOW SettingAdjustment of GAS Pressure Regulator Adjustment of Broiler BurnersParts Prop Gas Components INFRARED/RADIANT Compact Broiler Infrared Compact Broiler